172-65205MA-04 (DC5A) 6 Oct 2021
4
Specifications
WARNING
DO NOT use for toxic, flammable or otherwise hazardous fluids.This product
is a separator trap for air that separates and discharges condensate from
air piping systems. Use only for air and/or air condensate. This product is for
intended use only. Improper use may result in such hazards as damage to
the product or malfunctions that may lead to serious accidents.
WARNING
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions which may lead to serious accidents. Local regulations
may restrict the use of this product to below the conditions quoted.
CAUTION
DO NOT use this product in excess of the maximum operating pressure
differential; such use could make discharge impossible (blocked).
CAUTION
Use only under conditions in which no freeze-up will occur. Freezing
may damage the product, leading to fluid discharge, which may cause
burns or other injury.
CAUTION
Refer to the product nameplate for detailed specifications.
* Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are
PRESSURE SHELL DESIGN CONDITIONS,
NOT
OPERATING CONDITIONS.
** Valve No. is displayed for products with options. This item is omitted from the nameplate
when there are no options.
Model
Maximum Allowable
Temperature (TMA)*
Maximum Allowable
Pressure*
Nominal Diameter
Maximum Differential
Pressure
Production Lot No.
Valve No.**
Maximum Operating
Temperature