background image

Radio module WZU-RF, WZU-RF-EXT 

Subject to change 

 

x

  Press the button 2 until 

 (exemplary; 

see LCD displays) appears on the display. 

x

  Press the button 1 until 

 appears. 

x

  Press the button 2. 

7. 

Technical data 

Standard 

Open Metering System Specification Vol.2 

Issue 2.0.0: 2009 or 4.1.2: 2016 

EN 13757-3:2016; EN 13757-4:2014 

Transmission frequency 

for T1 

868.95 MHz  

(min. 868.90 MHz to max. 869.00 MHz) 

Transmission frequency 
for C1 

868.95 MHz (min. 868.928 MHz to max. 
868.972 MHz) 

Transmission power 

(ERP) 

Min. 3.16 mW (5 dBm) to max. 25 mW 

(13.9 dBm) 

Range *) 

Free field 

 

Up to max. 400 m 

Inside building 

e. g. horizontally 30 meter 

Power supply  

 

via meter **) 

Battery type D 

Mobile radio (16 seconds) battery for 11 years 

Stationary radio (15 minutes) battery for 16 

years 

via power supply 

110 / 230 / 24 V 

Sending interval 

Mobile data reading 

Stationary data 

reading 

User defined data 

telegrams 

 
16 seconds 

 

15 minutes 

 

acc. to telegram length 16 - 900 seconds 

*) Can deviate significantly depending on the structure of the building.  
**) If the battery of the meter is of any other type, it must be replaced by a 

battery of type D. This battery life time is valid for the standard data tele-

grams (P600, P601) and T550 with standard measuring interval for flow and 

temperature. 

8. 

Ordering data 

As accessory 

WZU-RF 

With integrated anten-

na 

 

WZU-RF-EXT 

With external antenna 

For power pack  WZU-AC110-xxx 

 

 

WZU-ACD230-xxx 

 

 

WZU-ACDC24-00 

 

For meters with 

radio module 

1

UH50-xxxx-xxxx-xxx-YxZx-xxx 
UC50- xxxx-xxxx-xxx-YxZx-xxx 

 

OMS 

v2.0

, T1, 

Profil A (Mode 

5) 

Z = E 

Module with integrated 

antenna 

 

Z = F 

Module with external 

antenna 

OMS 

v4.1.2

 

(BSI), T1 oder 
C1, Profil B 

(Mode 7)

 

Z = Q 

Module with integrated 
antenna 

 

Z = W 

Module with external 

antenna 

 

Y = E, F 

Battery operation D-

cell 11 years, 16 years 

 

Y = R 

Supply voltage 110 V 

 

Y = N, P 

Supply voltage 230 V 

 

Y = M 

Supply voltage 

24 V ACDC 

1

) For processing your order of meters with radio module, additional ordering 

information for the required parameterization in the production are needed 
(see for example the respective 

Technical Description

). 

 
 

Gyr GmbH 

Humboldtstrasse 64 

90459 Nuremberg 

Germany 

Summary of Contents for WZU-RF

Page 1: ...velops open and vendor independent specifications for communication interfaces and basic requirements for meters http oms group org 3 Installation and assembly Up to 2 communication modules can be installed Number Description 1 Service button under the housing cover 2 Slot module 1 3 Slot module 2 4 Bushing for power cable 5 Cable grommets Note You will find the permitted module combina tions in t...

Page 2: ...the manufacturer Adaption can be done by using the service software UltraAssist Attention Changes in the data telegram or the transmission rate affect the battery life Note Detailed information for the parameterization with the service software can be found in the UltraAs sist user manual Note Support for ordering can be found in the Tech nical Description 6 1 Call up parameterization operation To...

Page 3: ...nce between the transmission and the fetching of the data x Put a tick by Age of Data Note In Germany this option must be activated when connected to a Smart Meter Gateway 6 4 Apply settings Proceed as follows to apply the settings x Click on the OK button After a successful parameterization the following message appears OMS Parameters have been set 6 5 Leave parameterization Proceed as follows to...

Page 4: ...ignificantly depending on the structure of the building If the battery of the meter is of any other type it must be replaced by a battery of type D This battery life time is valid for the standard data tele grams P600 P601 and T550 with standard measuring interval for flow and temperature 8 Ordering data As accessory WZU RF With integrated anten na WZU RF EXT With external antenna For power pack W...

Reviews: