background image

Radio module WZU-RF, WZU-RF-EXT 

Subject to change 

 

The following data telegrams can be ordered: 

x

 

Stationary P600 

 with current values: 

ƒ

 

Current energy 

ƒ

 

Current volume 

ƒ

 

Current flow 

ƒ

 

Current power 

ƒ

 

Current temperatures hot and cold side 

ƒ

 

Errors (manufacturer specific) 

ƒ

 

Current time stamp (type I) 

x

 

Mobile P601 

 with monthly and yearly set day: 

ƒ

 

Current energy 

ƒ

 

Current volume 

ƒ

 

Energy on monthly set day 

ƒ

 

Volume on monthly set day 

ƒ

 

Monthly set day 

ƒ

 

Energy at yearly set day 

ƒ

 

Yearly set day 

ƒ

 

Error (manufacturer specific) 

ƒ

 

Current time stamp (type I) 

x

 

Mobile P602 

 with tariffs, cold / heat: 

ƒ

 

Current energy 

ƒ

 

Tariff register 1 

ƒ

 

Tariff register 2 

ƒ

 

Storage date 1. previous month 

ƒ

 

Heat quantity previous year 

ƒ

 

Tariff register 1. previous month 

ƒ

 

Tariff register 2. previous month 

ƒ

 

Errors (manufacturer specific) 

ƒ

 

Errors (manufacturer specific) 

The data telegrams can also be parameterized with the service 
software UltraAssist afterwards. 

5. 

LCD 

 

Note:

 Both display range and data displayed can differ 

from  this  description  depending  on  the  meter  parame-
terization. Certain button functions can also be blocked. 

Service loop “

LOOP 4

 

 

Head of the loop 

 

 

 

Type 

“RF” in slot module 2 

in 2-sec. cycles 

with send mode 

“Turned off

 (rf off)

 

or “Turned on

 (rf on)

see additional notes in 6.6 

 

or

 

 

or

 

 

or

 

 

or

 

 

 

or

 

 

 

 

6. 

Parameterization 

The parameters for the radio operation such as 

x

 

Radio mode, 

x

 

Encryption, 

x

 

Data telegram / telegram composition, 

x

 

Transmission interval, 

are pre-parameterized by the manufacturer. Adaption can be 
done by using the service software UltraAssist. 

 

Attention

:  Changes  in  the  data  telegram  or  the 

transmission rate affect the battery life. 

 

Note:

  Detailed  information  for  the  parameterization 

with the service software can be found in the UltraAs-
sist user manual. 

 

Note: 

Support for ordering can be found in the Tech-

nical Description. 

6.1 

Call up parameterization operation 

To call up the parameterization mode, proceed as follows: 

x

 

Hold the service button for about 3 seconds, until

 appears on the LCD. 

6.2 

Starting the service software UltraAssist 

To start the service software, proceed as follows: 

x

 

Put the optical head on the optical interface. 

x

 

Start the service software. 

The service software starts automatically the status query. 
After a few seconds the following message appears: 

Type T550 as UX50 (Version X. XX/ X.XX / flashversion) in Pb 

(with calibration seal) found.”

 

If the service software is already started, just click on the 

 

icon in the Quick launch bar. 

6.3 

Parameterization 

To parameterize the radio module, proceed as follows: 

x

 

Select the menu 

Parameterization

Æ

 

Radio Module 868 MHz

 

The following window appears for T550 

(UH50…)

 

 FW 5.23. For 

T550 

(UH50)

 

<  FW  5.23  the  new  functions  are  not  offered  for 

selection: 

 

 

The following parameters can be configured: 

 

Note:

  The  parameters  have  to  be  adapted  to  the  de-

ployed radio receiver. 

 
1.  Radio mode and encryption (security profile acc. OMS)

 [1]

 

 

Note:

 The module sends in T1 or C1 mode (unidirec-

tional) acc. to EN 13757-4. 

 

Note:

 For data security, encryption acc. to OMS is 

available: security profile A (Encryption Mode 5) or 
security profile B (Encryption Mode 7). 

Summary of Contents for WZU-RF

Page 1: ...velops open and vendor independent specifications for communication interfaces and basic requirements for meters http oms group org 3 Installation and assembly Up to 2 communication modules can be installed Number Description 1 Service button under the housing cover 2 Slot module 1 3 Slot module 2 4 Bushing for power cable 5 Cable grommets Note You will find the permitted module combina tions in t...

Page 2: ...the manufacturer Adaption can be done by using the service software UltraAssist Attention Changes in the data telegram or the transmission rate affect the battery life Note Detailed information for the parameterization with the service software can be found in the UltraAs sist user manual Note Support for ordering can be found in the Tech nical Description 6 1 Call up parameterization operation To...

Page 3: ...nce between the transmission and the fetching of the data x Put a tick by Age of Data Note In Germany this option must be activated when connected to a Smart Meter Gateway 6 4 Apply settings Proceed as follows to apply the settings x Click on the OK button After a successful parameterization the following message appears OMS Parameters have been set 6 5 Leave parameterization Proceed as follows to...

Page 4: ...ignificantly depending on the structure of the building If the battery of the meter is of any other type it must be replaced by a battery of type D This battery life time is valid for the standard data tele grams P600 P601 and T550 with standard measuring interval for flow and temperature 8 Ordering data As accessory WZU RF With integrated anten na WZU RF EXT With external antenna For power pack W...

Reviews: