Operating instructions 

 

Radio module WZU-RF, WZU-RF-EXT 

 

 

27.10.2017 

Translation 

 

 

Radio module WZU-RF, WZU-RF-EXT 

Subject to change 

 

1. 

Safety information 

 

Comply with ESD protection measures. 

 

Avoid short-circuits on the PCB 

 

Route connecting cables through the cable grommets 
of the meter only. 

 

Do  not  cut  the  grommets  shorter  than  necessary 
since this may lower the degree of protection. 

 

Changes  in  the  data  telegram  or  the  transmission 
rate affect the battery life. 

 

The meter sends no data telegram after delivery ex-
factory.  The  transmission  starts  after  the  installation 
of the meter. 

 

The  module  must  not  be  plugged  in  during  test-
ing / calibrating a meter on a test bench!  For mount-
ing  or  removing  the  module,  the  6-pole  connector 
shall be used for handling only! 

2. 

Description of function 

The radio module 

(firmware 

 4.69, see label on the rear side) 

is

 

an 

add-on  module  for  the  following  types  of meter:  T550 

(UH50…)

 

firmware ≥ 5.17

 

and T550

 

(UC50…)

 

Note: 

For meter of the type T550 

(UH50…)

 firmware 

 

5.23,  new  functions  are  available  (C1  mode,  OMS 
4.1.2 with security profile B). 

The module  enables the meter to communicate with a mobile 
or stationary receiver using 868 MHz radio frequency. 
The module supports OMS

1

 - compliant data transmission. 

The radio module is available in 2 different versions: 

x

 

With integrated antenna (WZU-RF) 

 

x

 

With external antenna (WZU-RF-EXT; cable length about 
2,50 m) 

 

 

1

) Open Metering System Specification: Industry standard of a community of interest of 

companies and associations. It develops open and vendor independent specifications for 
communication interfaces and basic requirements for meters - http://oms-group.org 

3. 

Installation and assembly 

Up to 2 communication modules can be installed. 

 

 

Number 

Description 

Service button (under the housing cover) 

Slot “m

odule 1

 

Slot 

“m

odule 2

 

Bushing for power cable 

Cable grommets 

 

 

Note: 

You  will  find  the  permitted  module  combina-

tions  in  the  respective  Technical  Description.  The 
radio functions depend on the T550 firmware. 

Installing the communication module 

The communication modules are connected via a 6-pole reac-
tion-free connector so that installation or replacement is possi-
ble at any time. 
To install a communication module proceed as follows: 

x

  Press the 4 side lugs of the housing cover inwards and 

remove the cover. 

x

  Put the communication module into the correct position. 

 

Note:

  The  module  WZU-RF  and  WZU-RF-EXT  may 

be fitted at slot module 2 only. 

x

  Place the communication module carefully in both guide 

slots and push it in. 

x

  To connect the antenna of WZU-RF-EXT, open one grom-

met matching the cross section of the antenna cable. 

 

Note:

  Open  the  cable  grommets  in  such  a  way  that 

they enclose the cable tightly. 

x

  Guide the antenna cable through the grommet from out-

side. 

x

  Plug the antenna cable to the module. 

 

Note:

 When retrofitting a meter with radio module, the 

voltage  supply  must  be  checked  and,  if  necessary, 
replaced.  A  battery  type  D  or  a  power  supply  is  re-
quired to operate a radio module. 

4. 

OMS-compliant data output 

The  meter 

sends  data  telegrams  acc.  to  the  “open  metering 

system specification

x

 

Volume 2 Primary Communication Issue 2.0.0: 2009-07-20 
or 

x

 

Volume 2 Primary Communication Issue 4.1.2: 2016-12-16 

Summary of Contents for WZU-RF

Page 1: ...velops open and vendor independent specifications for communication interfaces and basic requirements for meters http oms group org 3 Installation and assembly Up to 2 communication modules can be installed Number Description 1 Service button under the housing cover 2 Slot module 1 3 Slot module 2 4 Bushing for power cable 5 Cable grommets Note You will find the permitted module combina tions in t...

Page 2: ...the manufacturer Adaption can be done by using the service software UltraAssist Attention Changes in the data telegram or the transmission rate affect the battery life Note Detailed information for the parameterization with the service software can be found in the UltraAs sist user manual Note Support for ordering can be found in the Tech nical Description 6 1 Call up parameterization operation To...

Page 3: ...nce between the transmission and the fetching of the data x Put a tick by Age of Data Note In Germany this option must be activated when connected to a Smart Meter Gateway 6 4 Apply settings Proceed as follows to apply the settings x Click on the OK button After a successful parameterization the following message appears OMS Parameters have been set 6 5 Leave parameterization Proceed as follows to...

Page 4: ...ignificantly depending on the structure of the building If the battery of the meter is of any other type it must be replaced by a battery of type D This battery life time is valid for the standard data tele grams P600 P601 and T550 with standard measuring interval for flow and temperature 8 Ordering data As accessory WZU RF With integrated anten na WZU RF EXT With external antenna For power pack W...

Reviews: