Installation and user manual
14
Stand 09/17
Sketch 7
If you need an extension for the mains adaptor, a 2-pole cable with
plug and socket is available (item no. 8640033). Push the socket onto
the 2-pole cable of the mains adaptor. Push the plug onto the
extension cable and connect the cable to Power and GND of terminal
X1 (refer Figure 6).
C 4.5 Infrared emitter connection
The infrared emitters are connected to terminal strip X1 on terminals
3 and 4 (or 5 and 6). Ensure correct polarity of the transmitting
diodes.
The red marked cable of the IR emitter is always connected to
terminals IR1 or IR2. The coppery cable of the IR emitter is
connected to the terminal GND.
The IR emitter is sticked directly to the IR receiver of the end device.
C 4.5.1 Connection options IR emitter
Up to two IR emitters can be connected per output.
For this you can have from TLS one single IR emitter (Ident.-No. 864
0027) and/or a double IR emitter (Ident.-No. 864 0028).
These can be combined with each other, in which the maximum
number of IR emitters per output must not be exceeded.
1
2
3
4
5
6
7
8
9
Power
GND
GND
IR1
IR2
GND
-----
-----
GND
8640033 Power cable - OL
X1
8705567
Female 2pin,
for clamping
8705568
Male 2pin,
for screwing
AC adaptor
AC adaptor
Extension cable
GND
- brown wire
black/black-white wire
- white wire
1 Power
2 GND
3 IR1
4 GND
5 IR2
6 GND
7 TxD
8 GND
9 IN-SS
X1
The AC adaptor has to be connected to
terminals 1 und 2 of the terminal strip
X1. Please note the right polarity of the
AC adaptor. Brown wire to terminal
GND. White wire to terminal Power.
AC adaptor
GND
black/black white wire
Extension cable
- brown wire
- white wire
8640033 Power cable OL