background image

Cargo Liquid Sampling Device   

 

   

 

TKT-TSS-02 (REV. 2) 
Issue date : 2008.07.08

                                                 

 

     

      SHEET NO. : 6/10 

 

 

 

5. Operation for Cargo Liquid Sampling Device 

 

5-1. General Description

 

Thank you for purchasing the Sampling equipment of TANKTECH . 

Products of the our company intend to manage cargo tanker of the land and the marine efficiently. 

Before products use, Please carefully read this manual.   

Please, ask to users for the right usage to operate the products well. 

 

5-2. About Mark of the Manual 

This  manual  is  written  with  [

Warning

]  and  [

Caution

]  markings.  These  are  important  for  a  safe  operation. 

These  precautions  stress  the  important  matter  for  the  prevention  of  the  physical  accident  and  possible 

damage to the equipment. 

 

 

 

 

 

 

5-3. Application for Model : T2000-TSS-02   

Sampling Capacity : Approx. 0.5Liter 

 

5-4. Name and Shape of Structure 

This device is constructed the sampling bottle part, measuring tape to fix the bottle and indicate the depth   

of bottle, reel part to move the measuring tape and frame part to fix all device and connect the shut on-off   

valve of TANKTECH. 

 

5-5. Sampling Method 

1. Connect the suitable bottle with the end of the measuring tape by using the hook. 

    Insert the bottle into storage barrel and fix it with latch. 

 

Fig 1. Connect of Cargo Liquid Sampling Device 

 

CARGO LIQUID SAMPLING DEVICE 

FOR CARGO LIQUID SAMPLING 

 

Warning :   

When wrong use of equipment may cause body harm to user.   

 

Caution :   

When wrong use of equipment may cause damage to the set.

 

Summary of Contents for T2000-TSS-02

Page 1: ...S 02 Gas Tight Closed Type MODEL T2000 TSS 02 Protect operator Protect environmental pollution Easy construction Easy operation maintenance Benefits of T2000 TSS 02 Instruction Manual For Cargo Liquid Sampling Device ...

Page 2: ...ng System 3 Installation for Cargo Liquid Sampling Device 4 Specification for Cargo Liquid Sampling Device Model T2000 TSS 02 5 Operation for Cargo Liquid Sampling Device Model T2000 TSS 02 TANKTECH CO LTD HEAD OFFICE 1506 2 Songjeong dong Gangseo gu Busan 618 270 KOREA TEL 82 51 979 1600 FAX 82 51 979 1601 E MAIL tanktech tanktech co kr http www tanktech co kr ...

Page 3: ...FG N O M ADE I N KOREA O N MFG D ATE T20 0 0 TF C 02 GAS I NT ERM I TTENT BEEP 0 06 2 05 M F G NO M F G DAT E M ODE L W AT ER C ONTI NUOUS BEEP P ORTA B LE OI L WA TE RI NT E RF A CE DE T E CT O R O N O FF OI L FREQU ENT BEEP ON O FF T2 0 00 T FC 0 1 M ADE I N KOREA DI S P LA Y O I L F REQUEN TBEEP W ATER CON TI NU OUS BEEP G AS I NTER M I TTENTBEEP GAS I NT ERM I TTENT BEEP OI L FREQU ENT BEEP W ...

Page 4: ...Cargo Liquid Sampling Device TKT TSS 02 REV 2 Issue date 2008 07 08 SHEET NO 4 10 3 Installation for Cargo Liquid Sampling Device TANKTECH TANKTECH ON OFF ON OFF ...

Page 5: ...the cargo liquid 4 2 Model No T2000 TSS 02 Tape length 30M Tape graduation Scale graduation Metric Tape resolution 1 Ball valve coupling Top mounting of model TVC 02 PF 2 1 4 TAP Overall dimensions height width thickness APP 950 346 180 Capacity of sampling bottles 0 5 Liter Weight 9 1 kg 4 3 Material MODEL T2000 TSS 02 Body Aluminum casting JIS AC4C T6 4 4 Coating IN OUT SIDE Epoxy nylon coating ...

Page 6: ... the prevention of the physical accident and possible damage to the equipment 5 3 Application for Model T2000 TSS 02 Sampling Capacity Approx 0 5Liter 5 4 Name and Shape of Structure This device is constructed the sampling bottle part measuring tape to fix the bottle and indicate the depth of bottle reel part to move the measuring tape and frame part to fix all device and connect the shut on off v...

Page 7: ...e shut on off valve connect the sampling device at the valve Fig 2 Remove the cap for Model TVC 02 Fig 3 Detail of Seal part MODEL TVC 02 Shut On Off valve Gauging Station installed on tank top it is available to draw up cargo liquid sample in any desired level without releasing dangerous vapor from tank ...

Page 8: ...g Device TKT TSS 02 REV 2 Issue date 2008 07 08 SHEET NO 8 10 3 Open the shut on off valve OPEN C L O S E O P E N CLOSE Fig 4 Open handle position 4 Pull handle and drop the sampling bottle slowly Fig 5 Reel handle breaker ...

Page 9: ... 10 5 Drop the sampling bottle at the wanted position REWIND Fig 6 Mark of Wind Rewind 6 Stop the sampling bottle at the wanted position 7 Turn the cleaner knob on before rewinding the sampling bottle RESET POISITION AFTER CLEANING Fig 7 View of cleaning position Do not free fall ...

Page 10: ...CLOSE OPEN O P E N C L O S E C L O S E O P E N CLOSE OPEN Fig 8 View of Liquid winding up 9 Separate the barrel from the sampling device separate the sampling bottle from the measuring tape 10 Auto Open Drain the Check ball or disc at bottle bottom bottle the liquid sample O P E N C L O S E CLOSE OPEN Fig 9 View of Auto Open Drain the Check ball or disc ...