TKH Security Proposal | RFP Name | RFP Number
TKH Security | Siqura INT-RJ, INT-SM |
Installation manual
8
INT-SM5, INT-SM10
1. 3x 1.5mm
2
(Black1 - N, Black2 - L, Yellow/green - PE)
2. 4x 2x 0.53 mm, Cat. 6A, F/UTP Black (Not Connected)
3. 2x 2x 0.22 mm², FTP.
a. Grey jacket: Washer control (24Vac)
b. Black jacket: Not connected
4. 4x 9
m/125
m (OS1). 2x terminated with SC, 2x spare (not connected)
5. 2x 50
m/125
m (OM2). Not terminated
Spare fibers
The two unterminated SM-fibers can be used as spare if one of the originals breaks or gets
serious damaged. Inside the camera and at the end of the cable the spare pigtails have 30
cm to 50 cm slack, respectively. When one of the original fibers are damaged, specialized
and trained personnel can terminate the cable with the SC optical fiber connectors.
Note
: Please, make sure that the unused, spare fibers are carefully and tightly stored in the
junction box, so that they can be used later when necessary.