TKH Security | Siqura EX-PD24 | 

Installation manual

   

 

 

 

INT-RJ / -SM / -MM 

Installation manual 

Summary of Contents for INT-MM

Page 1: ...TKH TKH Security Siqura EX PD24 Installation manual 1 INT RJ SM MM Installation manual ...

Page 2: ...s We invite you to offer your suggestions and comments by email via info tkhsecurity com Your feedback will help us to further improve our documentation How to contact us If you have any comments or queries concerning any aspect related to the product do not hesitate to contact TKH Security B V Meridiaan 32 2801 DA Gouda Used electrical electronic and stainless steel products should not be mixed w...

Page 3: ...n manual v2 3 Contents Contents 3 Description 4 Safe Area SA camera housing 4 Hazardous Area Ex camera housing 4 Before you continue 5 Installation of the unit 6 Installation instruction 7 INT RJ INT SM INT MM 7 INT RJ5 INT RJ10 7 INT SM5 INT SM10 8 ...

Page 4: ...le with an external cable tail Hazardous Area Ex camera housing The Atex or EX camera housings require a pre installed cable tail The INT RJ5 or INT RJ10 define a EX cable tail for 100 Mb Fast Ethernet of 5 or 10 meter INT SM5 or INT SM10 defines a single mode connection with a 5 or 10 meter multicable and INT MM similar for multi mode The cable is terminated by two Ex d barrier glands on both sid...

Page 5: ... must be tightly closed when operating Open only the covers pointed out in this installation manual Other covers should be open only by the manufacturer For security reasons install the unit out of the reach of children For security reasons do not install the unit in the proximity of water containers and never push objects or pour liquids into the unit The unit can be safely used in damp environme...

Page 6: ...ed fuse T Time delay of at least 4 A or fuse of 10 A max Or equivalent resettable devices such as magnetothermal fuses These ratings include inrush current for startup or temporary overload It must be very quickly recognizable and readily accessible For connection to the 24Vac use a multipolar cable having minimum 3x1 5 mm2 15 AWG The mains cable must be protected An all pole mains switch with an ...

Page 7: ...curity Siqura EX PD24 Installation manual 7 Installation instruction INT RJ INT SM INT MM The interfaces are located in the camera Refer to the camera s installation manual for more information Cable glands and cable are not included INT RJ5 INT RJ10 ...

Page 8: ...ected 5 2x 50 m 125 m OM2 Not terminated Spare fibers The two unterminated SM fibers can be used as spare if one of the originals breaks or gets serious damaged Inside the camera and at the end of the cable the spare pigtails have 30 cm to 50 cm slack respectively When one of the original fibers are damaged specialized and trained personnel can terminate the cable with the SC optical fiber connect...

Page 9: ...lation manual 9 INT MM5 INT MM10 1 3x 1 5mm2 Black1 N Black2 L Yellow green PE 2 4x 2x 0 53 mm Cat 6A F UTP Black Not Connected 3 2x 2x 0 22 mm FTP a Grey jacket Washer control 24Vac b Black jacket Not connected 4 4x 9 m 125 m OS1 Not connected 5 2x 50 m 125 m OM2 Terminated with SC ...

Page 10: ...TKH Security Proposal RFP Name RFP Number TKH Security Siqura INT RJ INT SM Installation manual 10 Our Brands 2020 TKH Security tkhsecurity com 2021 TKH Security B V Our Brands ...