on the device.
Inclusion
hit the button on the device.
Exclusion
hit the button on the device.
Product Usage
The device is able to dim electric load up to 300 W. Short press of the button will toggle. This means that the power will be turned on if it was off and turned
off when it was on. When switching the lamp on or off the light will dim for about 2 seconds until the final level is reached.
The the button is constantly pressed the light will be dimmed. The dimming function will also toggle. Constantly pressing the the button will either dim up or
dim down the light until it reaches the final level.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
1. Make sure a device is in factory reset state before including. In doubt exclude before include.
2. If inclusion still fails, check if both devices use the same frequency.
3. Remove all dead devices from associations. Otherwise you will see severe delays.
4. Never use sleeping battery devices without a central controller.
5. Dont poll FLIRS devices.
6. Make sure to have enough mains powered device to benefit from the meshing
Association - one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a
different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups
and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective
association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number
Maximum Nodes
Description
1
5
Lifeline
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock
further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be
the desired value minus 256. For example: To set a parameter to 200
it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte
value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 1: Indicator Light
Change the state of indicator lite
Size: 1 Byte, Default Value: 1
Setting
Description
0
The LED is On, if the device is on
1
The LED is On, if the device is Off
Parameter 2: Memory function
Save the last status or not.
Size: 1 Byte, Default Value: 1
Setting
Description
0
Do not save the last status
1
Save the last status
Technical Data