background image

MAINTENANCE

The X

CHANGE

R

TM

hood screen must be inspected every 3 to 6 months. Remove any

foreign material such as leaves, lint, cottonwood or other items. Remove screen to
clean if necessary. Replace screen with bent edge facing up and in the front of hood,
(See Diagram R).

HOW HOW TO OBTAIN SERVICE ASSISTANCE

1.

If you have any questions about your X

CHANGE

R

TM

or if it requires adjustment, repair or routine maintenance, we suggest 

that you contact your installer, contractor or service agency. 

2.

If you require technical information contact Tjernlund Products, Inc. at 1-800-255-4208 or email us at [email protected].

When contacting Tjernlund Products, Inc., please have the following information available:

1.

Model number and date code of the X

CHANGE

R

TM

2.

Name and address of installer and service agency

3.

Date of original installation and dates any service work was performed

4.

Details of the problem

LIMITED PARTS WARRANTY AND CLAIM PROCEDURE

Tjernlund Products, Inc. warrants the components of the X

CHANGE

R

TM

for one year from date of installation. This warranty covers

defects in material and workmanship. This warranty does not cover normal maintenance, transportation or installation charges for
replacement parts or any other service calls or repairs. This warranty DOES NOT cover the complete X

CHANGE

R

TM

if it is operative,

except for the defective part.

Tjernlund Products, Inc. will issue credit or provide a free part to replace one that becomes defective during the one year warranty
period. All receipts should include the date code of the X

CHANGE

R

TM

to ensure that the defective component corresponds with the

complete unit. This will help prevent possible credit refusal.

1.)

Follow troubleshooting guide to determine defective component. If unable to determine faulty component, contact your 
Tjernlund distributor, Tjernlund Products Technical Customer Service Department at 1-800-255-4208 for troubleshooting 
assistance or email us at [email protected].

2.)

After the faulty component is determined, return it to your Tjernlund distributor for replacement. Please include X

CHANGE

R

TM

date code component was taken from. Credit or replacement will only be issued to a Tjernlund distributor after the defective 
part has been returned prepaid to Tjernlund.

WHAT IS NOT COVERED

Product installed contrary to our installation instructions
Product that has been altered, neglected or misused
Any freight charges related to the return of the defective part
Any labor charges related to evaluating and replacing the defective part

XCHANGER PARTS AND ACCESSORIES

REPLACEMENT PARTS

X

CHANGE

R

TM

Fan Assembly                               

950-8350

X

CHANGE

R

TM

Dehumidistat 950-8351

X

CHANGE

R

TM

X2D Hood Screen

950-8352

ACCESSORIES

6” Duct Take-Off Kit

DT2-6

Plug-In Speed Control

SCP

7

TJERNLUND LIMITED 1 YEAR WARRANTY

Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1)
year from the date of original purchase or delivery to the original purchaser, whichever is earlier.  Remedies under this warranty are limited to repairing or replacing, at our
option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid.  THERE ARE
NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT.  THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WAR-
RANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY.  IMPLIED WAR-
RANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so that
limitation may not apply to you.  In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or exclu-
sion may not apply to you.  This warranty gives you specific legal rights and you may also have other rights which may vary from state to state.  Send all inquiries regard-
ing warranty work to Tjernlund Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794.  Phone (651) 426-2993 • (800) 255-4208 • Fax (651) 426-9547 • Email
[email protected].

DIAGRAM R

INSERT HOOD
SCREEN WITH BENT
EDGE FACING UP AT
FRONT OF HOOD.

Summary of Contents for XCHANGER X2D

Page 1: ...rights reserved P N 8504164 THIS DEVICE MUST BE INSTALLED BY A QUALIFIED PERSON READ INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION AND OPERATION OF THE XCHANGER REV A 05 10 TJERNLUND PRODUCTS INC 1601 Ninth Street White Bear Lake MN 55110 6794 PHONE 800 255 4208 651 426 2993 FAX 651 426 9547 Visit our web site www tjernlund com ...

Page 2: ... SPECIFICATIONS GENERAL INFORMATION Each XCHANGERTM is electrically factory line tested before shipment After opening carton Inspect thoroughly for hidden damage INSTALLATION RESTRICTIONS WARNING Improper installation adjustment alterations service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service ...

Page 3: ...ENDED PATTERNS OF OPERATION The XCHANGERTM X2D model includes a dehumidistat control which can cycle the XCHANGERTM fan s automatically based on the rel ative humidity level of the house or it can be operated based on recommendations below It is generally recommended to maintain a Relative Humidity RH below 60 to inhibit mold growth A standard plug in wall timer can be programmed based on the life...

Page 4: ...Do not exhaust air from mechanical room unless makeup air is also supplied or equipment in mechanical room is sealed combustion Carbon monoxide poisoning may result Use the DT2 6 6 duct take off kit so exhaust can be removed from outside the mechanical room if necessary It is required that the XCHANGERTM be installed in a location where it will not be directed at the occupants Do not discharge int...

Page 5: ...g ensuring XCHANGERTM will be level 2 CAUTION When cutting or drilling into wall do not damage electrical wiring and other hidden utilities Using a 1 2 bit drill pilot holes noted on the template from inside through rim joist wall board siding etc keeping drill bit perpendicular to the wall 1 2 bit must be long enough to penetrate through exterior 3 Use a level to mark 4 holes drilled in step 2 an...

Page 6: ... see Diagram K 10 Insert plastic nut into XCHANGERTM base Assemble mounting bracket as shown See Diagram M Attach assembled bracket to bottom of XCHANGERTM Mark bracket mounting location on wall with a slight upward pitch in rear of XCHANGERTM and connect to wall using provided wall anchor See Diagram L 5 DIAGRAM F DIAGRAM E DIAGRAM G INSERT 6 PUSH CLIPS THROUGH EMBOSSED HOLES OF HOUSING CLIPS MUS...

Page 7: ...side outlets IMPORTANT Do not plug other devices into dehumidistat control or damage may result Once fans are installed in XCHANGERTM plug dehumidistat control into standard outlet The XCHANGERTM control module includes an adjustable dehumidistat control which activates the fan s if the relative humidity rises above the selected set point It is gener ally recommended to maintain a Relative Humidit...

Page 8: ... was taken from Credit or replacement will only be issued to a Tjernlund distributor after the defective part has been returned prepaid to Tjernlund WHAT IS NOT COVERED Product installed contrary to our installation instructions Product that has been altered neglected or misused Any freight charges related to the return of the defective part Any labor charges related to evaluating and replacing th...

Reviews: