TJERNLUND XCHANGER X2D Installation Instructions Manual Download Page 6

4. Remove fans if necessary and insert X

CHANGE

R

TM

housing through exterior wall opening with fan openings facing down, 

(See Diagram H). For vinyl or other types of lap siding, level X

CHANGE

R

TM

and trace outer flange on X

CHANGE

R

TM

housing and 

trim siding back enough to install J channel or appropriate flashing, (See Diagram E). 

5. Insert (6) push clips through embossed holes of housing. Direction of clips must be as shown, (See Diagram F).

6. Place a bead of caulk on X

CHANGE

R

TM

mounting flange or building sheathing before inserting housing, (See Diagram G).

7. Remove fans if necessary and insert X

CHANGE

R

TM

housing through exterior wall opening with fan openings facing down, (See Diagram H). 

8. Level housing and secure to wall using (4) screws, (See Diagram I). Install J channel or appropriate flashing around X

CHANGE

R

TM

mounting flange. Do not cover up mounting flange or hood will not snap on push clips, (See Diagram J).

9. Carefully align and then snap hood on (6) push clips. Apply a bead of caulk around hood 

and siding, (see Diagram K).

10. Insert plastic nut into X

CHANGE

R

TM

base. Assemble mounting bracket as shown, 

(See Diagram M). Attach assembled bracket to bottom of X

CHANGE

R

TM

. Mark bracket 

mounting location on wall with a slight upward pitch in rear of X

CHANGE

R

TM

and connect 

to wall using provided wall anchor, (See Diagram L).

5

DIAGRAM F

DIAGRAM E

DIAGRAM G

INSERT (6) PUSH CLIPS THROUGH EMBOSSED
HOLES OF HOUSING. CLIPS MUST BE INSERTED AS
SHOWN.

LEVEL XCHANGER AND TRACE FLANGE. TRIM
SIDING BACK SO XCHANGER FLANGE CAN BE
MOUNTED FLUSH TO EXTERIOR SHEATHING.

PLACE A BEAD OF CAULK ON XCHANGER
MOUNTING FLANGE OR BUILDING SHEATHING
BEFORE INSERTING HOUSING. 

DIAGRAM J

INSTALL J CHANNEL OR APPROPRIATE FLASHING
AROUND XCHANGER MOUNTING FLANGE.

DIAGRAM M

ASSEMBLE XCHANGER MOUNTING BRACKET.

DIAGRAM L

ATTACH MOUNTING BRACKET TO BOTTOM OF
XCHANGER. INSTALL BRACKET SO XCHANG-
ER HAS A SLIGHT UPWARD PITCH IN REAR.

INSERT PLASTIC NUT
INTO XCHANGER BASE

WALL
ANCHOR 

DIAGRAM I

LEVEL HOUSING AND SECURE TO WALL USING
(4) SCREWS.

DIAGRAM K

CAREFULLY ALIGN AND THEN SNAP HOOD ON (6)
PUSH CLIPS. APPLY A BEAD OF CAULK AROUND
HOOD AND SIDING.

DIAGRAM H

INSERT XCHANGER HOUSING THROUGH WALL.
FAN OPENINGS MUST FACE DOWN.

FAN OPENINGS FACING DOWN

Summary of Contents for XCHANGER X2D

Page 1: ...rights reserved P N 8504164 THIS DEVICE MUST BE INSTALLED BY A QUALIFIED PERSON READ INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION AND OPERATION OF THE XCHANGER REV A 05 10 TJERNLUND PRODUCTS INC 1601 Ninth Street White Bear Lake MN 55110 6794 PHONE 800 255 4208 651 426 2993 FAX 651 426 9547 Visit our web site www tjernlund com ...

Page 2: ... SPECIFICATIONS GENERAL INFORMATION Each XCHANGERTM is electrically factory line tested before shipment After opening carton Inspect thoroughly for hidden damage INSTALLATION RESTRICTIONS WARNING Improper installation adjustment alterations service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service ...

Page 3: ...ENDED PATTERNS OF OPERATION The XCHANGERTM X2D model includes a dehumidistat control which can cycle the XCHANGERTM fan s automatically based on the rel ative humidity level of the house or it can be operated based on recommendations below It is generally recommended to maintain a Relative Humidity RH below 60 to inhibit mold growth A standard plug in wall timer can be programmed based on the life...

Page 4: ...Do not exhaust air from mechanical room unless makeup air is also supplied or equipment in mechanical room is sealed combustion Carbon monoxide poisoning may result Use the DT2 6 6 duct take off kit so exhaust can be removed from outside the mechanical room if necessary It is required that the XCHANGERTM be installed in a location where it will not be directed at the occupants Do not discharge int...

Page 5: ...g ensuring XCHANGERTM will be level 2 CAUTION When cutting or drilling into wall do not damage electrical wiring and other hidden utilities Using a 1 2 bit drill pilot holes noted on the template from inside through rim joist wall board siding etc keeping drill bit perpendicular to the wall 1 2 bit must be long enough to penetrate through exterior 3 Use a level to mark 4 holes drilled in step 2 an...

Page 6: ... see Diagram K 10 Insert plastic nut into XCHANGERTM base Assemble mounting bracket as shown See Diagram M Attach assembled bracket to bottom of XCHANGERTM Mark bracket mounting location on wall with a slight upward pitch in rear of XCHANGERTM and connect to wall using provided wall anchor See Diagram L 5 DIAGRAM F DIAGRAM E DIAGRAM G INSERT 6 PUSH CLIPS THROUGH EMBOSSED HOLES OF HOUSING CLIPS MUS...

Page 7: ...side outlets IMPORTANT Do not plug other devices into dehumidistat control or damage may result Once fans are installed in XCHANGERTM plug dehumidistat control into standard outlet The XCHANGERTM control module includes an adjustable dehumidistat control which activates the fan s if the relative humidity rises above the selected set point It is gener ally recommended to maintain a Relative Humidit...

Page 8: ... was taken from Credit or replacement will only be issued to a Tjernlund distributor after the defective part has been returned prepaid to Tjernlund WHAT IS NOT COVERED Product installed contrary to our installation instructions Product that has been altered neglected or misused Any freight charges related to the return of the defective part Any labor charges related to evaluating and replacing th...