ADNM-DTV   Flicker-Free TV Studio Camera Installation Instructions

7170445

Page 1 of 8

Installation Instructions

Please verify the contents of the packages!

Please read instructions entirely before starting installation
Be sure power is turned off before installing or modifying the 

system
Call Tivoli, LLC tech support with questions
Caution:
 This Power Supply is designed to work on 120-277V AC 

line voltage only. Use of any other power source will cause damage, 

shorten the life of the fixture and will void the warranty.
Consult any and all applicable local and national codes for 

installation.
Do not conceal or extend exposed conductors through a building 

wall as per local electrical code.
Warning: With any luminaire or power supply for any application, 

basic safety precautions should always be followed to reduce the risk 

of fire, electric shock and personal injuries. This power supply should 

be installed by a certified professional.

Profile Dimensions

R

10”

10”

4”

Mounting Location Requirements

It is recommended that the enclosure be mounted with at least 10” 

of open space around it for proper ventilation. Do not mount next to 

or above heat radiating equipment. Operating under high ambient 

temperature may increase the internal temperature and will require a 

de-rating in output current. This power supply will operate efficiently 

between -40° C to +80° C with adequate ventilation. The enclosure is 

NEMA 3R rated for outdoor/wet applications.

Outdoor Installation

Step 1: Locate Power Supply enclosure (NEMA 3R rated) in a suitable 

outdoor location. 

Step 2: Orient the box in the proper orientation for outdoor use. The 

solid cover must be positioned at the top to maintain water proof 

integrity.

Step 3: Note the spacing of the mounting holes when determining 

mounting location.

Step 4:  Knock out access holes as needed. The 12” Box has knockouts 

along the bottom of the box. The 16” does not include knockouts. Cut 

out access holes where needed. 

Caution! Be careful not to damage internal electrical components.

Step 5: Install strain reliefs (wire clamps) for ½” hole size. Input lead 

wires are 18AWG. Output lead wires are 14AWG. 

Input Connection:

Bring external Positive (Black) and Negative (White) Power Lines 

through Strain Relief on the input side of the Transformer. Connect 

to Black and White Transformer Leads using the correct size and UL 

approved Wire Nuts. 

Grounding: Connect the Green Ground Wire from inside the 

enclosure and the Green Transformer wire to incoming ground wire.

Note: The 6” X 8” box has only one Ground Wire.

Warnings and Cautions

1. Risk of electrical shock and energy hazard. All failures should be 

examined by a qualified technician. Do not open the case of the 

power supply module.

2. Do not install LED power supplies in places with high ambient 

temperature or close to a fire source. 

Summary of Contents for ADNM-DTV

Page 1: ...will require a de rating in output current This power supply will operate efficiently between 40 C to 80 C with adequate ventilation The enclosure is NEMA 3R rated for outdoor wet applications Outdoo...

Page 2: ...ircuit Installer is responsible for selecting the right size wire for run length and total wattage for each circuit Do not exceed rated watts per circuit Power Supply Connect transformer input to 120...

Page 3: ...wire to the VDC connector and the negative voltage supply wire to the VDC connector The driver and LEDs can use the same power supply EXT in Connect an external control device to the driver s Ext in a...

Page 4: ...nals will be reflected when they reach the end of the cable These reflections can cause eratic behavior lake random flashing lights wrong brightness levels etc To get the most reliable operation with...

Page 5: ...splay off M External input EXT INP LOG LIN Dimming curve M DIM CURV OFF VID COLR WHIT GLOW M M M M 1 512 Network resolution DMX address 8 BT 16 BT ADDR DMX RES NETW Interpolation AUTO MANU display off...

Page 6: ...roup 1 GND Group 2 Group 2 GND Group 3 Group 3 GND Group 4 Group 4 GND RGB LED strip R G B 32A PSU 6A 6A 6A 6A 6A 6A 6A 6A White LED strip 6A 24A 24A 18A TC Group 1 Group 1 GND Group 2 Group 2 GND Gro...

Page 7: ...Power Supply Negative Wire To Luminaire Positive Wire 16ga Wire DMX In DMX In DMX In Shield To TivoCue 22ga Wire G R B W Lead Wire W B G R 12V DC RGB Luminaire ADNM 60 1 5 12 DTV Outdoor Nema 3 Rated...

Page 8: ...6ga Wire Incoming Power To Luminaire 4 Circuits M LINEARdrive 720D 12 28V 24W Direct voltage controlled LED driver TC Group 1 Group 1 GND Group 2 Group 2 GND Group 3 Group 3 GND Group 4 Group 4 GND Ex...