background image

 

 

ORDINARY   MAINTENANCE 

Before initiating any maintenance operation, make sure that: 

 

the device is not connected to the power source. 

 

the device is at ambient temperature. 

Keep  the  internal  parts  and  the  grid    perfectly  clean.  Even  though  they  may  change  colour  and 
become brownish, never use abrasive or inflammable products for cleaning them. 
Keep the external parts perfectly clean that they have to be always specular to prevent corrosion and 
dust. 

 

PERIODIC   MONTHLY   MAINTENANCE

 

After removing the plug from the power socket, check that the fuses are not oxidised specially when 
the device is not used for a long time or kept in a humid ambient. 
The power socket should not change colour or oxidise. If that happens, replace it immediately. 
The power cable must be integral and it should not show cuts, abrasions or bending.  
The resistances and the internal electrical system do not require any maintenance. 
 

PERMITTED USES 

The  device  must  be  used  to  sterilize  metal  materials  whose  point  of  melting  is  higher  than  300°C 
(surgical  instruments, plates, and metal  screw). 
 

FORBIDDEN USES 

It  is  forbidden  to  place  in  the  device  items  whose  temperature  of  melting  is  lower  than 
300°C or it’s not known to the operator. 
 

ACCESSORY PARTS 

2 Internal shelves 
1 Mains cable 

SELLING OFF 

The sterilizing unit is made of various materials with mechanical, electro-mechanical and electronic 
parts. 
The selling off has to be made according with the regulations in force in the utilizing Nation. 

 

 

 

***ATTENTION*** 

 
 

Laboratory tests following a cycle of 120 minutes at 180ºC on Bacillus subtilis var niger ATCC 
9372 spores demonstrated the efficiency of the sterilizer.

 

 

Titanox  does  not  guarantee  and  cannot  ensure  the  effective  achievement  of  the  steril  state  of  the 
instruments placed in the sterilizer, according to the definition of steril medical instruments forseen 
by the EN 556 Norms. The user of the sterilizer therefore has the responsability to conduct all of the 
confirmation procedures of the sterilization process and the necessary verifications in order to ensure 
the effective completion of every single sterilization cycle. 

 

TECHNICAL SPECIFICATIONS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The  device  is  in  conformity  to  electrical  safety  norms  provided  for  by  the  normative 
institutes and supplied with bipolar plug which assures perfect electrical grounding. 

 

NON-COMPLIANCE WITH INSTRUCTIONS DESCRIBED IN THIS 

BOOKLET SHALL FREE COMPANY TITANOX S.R.L. FROM ANY 
LIABILITY. 

                   
                  Device type B. 
 
                  Caution! See the annexed documentation. 
 
                  Caution! Hot surface (max. 210°C). 
 
 
 
Available operation: 
 

TIME-PROGRAMMED: timer programmable up to 2 hours 

 

CONTINUOUS CYCLE: manual (without timer) 
 

 

Models: 

A3-213-400V 

A3-214-535V 

A3-215-670V 

Loaded Chamber 

3 kg 

4 kg 

5 kg 

External sizes: 

 

 

 

Width  mm 

565 

705 

835 

Height  mm 

410 

475 

550 

Depth  mm 

315 

420 

555 

Internal  Sizes: 

 

 

 

Width  mm 

405 

535 

670 

Height  mm 

220 

350 

430 

Depth  mm 

250 

325 

425 

Weights: 

 

 

 

Net  weight kg. 

13 kg 

22 kg 

35 kg 

Gross weight kg. 

15 kg 

25 kg 

41 kg 

Electrical  Characteristics: 

 

 

 

Nominal  tension (Voltage) 

230 V 

230 V 

230 V 

Nominal  power  (Watt) 

450 W 

950 W 

1900 W 

Nominal  frequency  (Hz) 

50/60 Hz 

50/60 Hz 

50/60 Hz 

Net’s  fuses (mm  5x20) 

F5A-250 V 

F5A-250 V 

F10A-250 V 

Ventilation motor (fan) 

23 W 

23 W 

23 W 

 

Summary of Contents for A3-213-400V

Page 1: ...C CR R I IT TA AL LY Y V Vi ia a C Ca an no ov ve e 2 2 A A C Ca an no ov ve e d dè è B Bi ia az zz zi i T Te el l 0 00 03 39 9 0 03 37 75 5 3 39 94 40 06 65 5 r r a a F Fa ax x 0 00 03 39 9 0 03 37 75 5 3 39 94 40 06 67 7 H Ho om me e p pa ag ge e h ht tt tp p w ww ww w t ti it ta an no ox x c co om m E E M Ma ai il l i in nf fo o t ti it ta an no ox x c co om m INSTRUCTIONS MANUAL DRY HEAT STERI...

Page 2: ...ndicated in these booklet instructions or in any case results from phenomenon unrelated to the normal working of the device 6 The warranty expires when the device is tampered with or repaired by unauthorised personnel 7 It is excluded the substitution and the extension of the warranty following a breakdown 8 It is excluded any compensation for damages direct or indirect of any nature to persons or...

Page 3: ...boratory tests following a cycle of 120 minutes at 180ºC on Bacillus subtilis var niger ATCC 9372 spores demonstrated the efficiency of the sterilizer Titanox does not guarantee and cannot ensure the effective achievement of the steril state of the instruments placed in the sterilizer according to the definition of steril medical instruments forseen by the EN 556 Norms The user of the sterilizer t...

Page 4: ...s in conformity to the safety norms in the country of installation Do not remove any label or plate in case of need ask for more Always insist on original spare parts Do not open the door of the device until the thermometer of the internal temperature do not indicate a temperature lower than 30 C TIME PROGRAMMED RUNNING 1 Insert the supplied connection socket of the mains cable in the plug of the ...