TITAN Technologies International, Inc.
®
9001 Jameel Street, Suite 180 • Houston, TX 77040
Toll-Free: 866.345.8484 • Phone: 281.449.9994 • Fax: 281.449.9996 • Email:[email protected]
http://www.titanti.com
Venting
Because air is compressible, air within the system can lead to accidents. It is
therefore essential to vent the system of air, prior to using the pump, hose and
tensioner before starting the work. To accomplish this, let the pump run at a low
pressure until the hydraulic system is fully vented.
•
Screw in the pressure limiting valve by approx. one revolution from the
point at which the spring takes effect, set switch I, to motor on, and vent
the entire system at the breather screw of the tensioner or at the end of
the hose until pure oil escapes without bubbles.
•
Make the desired pressure adjustment (Chap. Pressure adjustment).
Coupling of the high-pressure hoses
CAUTION: IT IS VERY IMPORTANT THAT THE TWO HALVES OF THE
COUPLING ARE ALWAYS CLEANED THROUGHLY BEFORE CONNECTING.
Dirt in the halves of the coupling also makes the complete connection more
difficult, obstructing the flow of fluid because it will be possible that the two balls
will not open fully.
NOTE: THEREFORE, PLEASE ALWAYS CHECK THAT THE COUPLING IS
FULLY ENGAGED OR, IF SCREW UNIONS ARE EMPLOYED, THAT THEY
ARE FULLY SCREWED IN.
NOTE: WE RECOMMEND THAT THE DUST CAPS SHOULD ALWAYS BE
SCREWED ON WHEN THE COUPLING IS DISCONNECTED.
WE WILL NOT ACCEPT GUARANTEE CLAIMS RESULTING FROM THE
INCORRECT USE OF OUR EQUIPMENT OR FROM THE USE OF
EQUIPMENT OR SPARE PARTS MADE BY OTHER MANUFACTURERS.
NOTE: QUALIFIED PERSONNEL MUST CONDUCT ALL REPAIRS OR
MODIFICATIONS TO THE PUMPS. INCORRECT HANDLING CAN CAUSE
THE GUARANTEE TO BE VOIDED.