TITAN Technologies International, Inc.
®
9001 Jameel Street, Suite 180 • Houston, TX 77040
Toll-Free: 866.345.8484 • Phone: 281.449.9994 • Fax: 281.449.9996 • Email:[email protected]
http://www.titanti.com
Trouble Shooting Chart
Most faults have a simple cause and can therefore be rectified on site, i.e. time
losses and transport costs can be avoided. Some of the most frequent faults are
explained below. If this information is insufficient, please consult our technical
support or your authorized
TITAN
®
Repair Facility.
Pump does not pressurize
•
Air in pump
Switch motor on and off several times
•
Changeover valve jammed
Switch by hand
•
Pressure converter defective
Replacement necessary
Pump pressurizes inadequately
•
Air in pump
Switch motor on and off several times
•
Gear wheels worn out
Replacement necessary
Pump does not reach pressure
•
Pump
worn
Replacement
necessary
•
Valve worn
Leak to tank
•
Relief valve misadjusted
Adjust pressure limiting valve
Pressure cannot be relieved
•
Solenoid valve jammed
Switch by hand
Technical data
1. Gear pump
Operating pressure p max:
230 bar
Conveyed volumes:
LP – 1.5 l/min until 4 l/min up to 230 bar
2.
Pressure Intensifier
3.
Converting ratio
1:13
Operating pressure p max:
2500 bar
Conveyed volumes:
HP – 0.9 l/min up to 2500 bar