12
NOTE
Do NOT remove the impeller
from its shaft.
Item #
Description
1
302701
Pump Volute (8097)
302728
Pump Volute (8098)
2
302702
Rubber Gasket
3
302703
Impeller (8097-78.4 MM)
302704
Impeller (8098-76.2 MM)
4
Pump Bracket
5
302705
Screw
6
302706
Mechanical Seal
7
Stator
8
302707
Lip Seal
9
Bearing
10
Rotor & Shaft
11
Pump Gasket
12
Bearing Housing
13
302708
Lock Nut
14
302709
Washer
15
302710
Rubber Seal
16
Top Cover
17
Screw
18
Grommet
19
Cord Screw
20
Power Cord
21
Capacitor
22
Handle
23
Oil Plug
CLEANING THE PUMP
1.
Always disconnect unit from power supply before any servicing is performed.
2.
Disconnect discharge piping and remove pump from sump basin.
3.
Submerse pump in a disinfectant solution (Clorox or chlorine) for at least one hour before disassembling pump.
4.
Unscrew the seven (7) stainless screws and gently pry volute from seal plate using a screwdriver.
5.
Use a flathead screwdriver to hold the shaft.
6.
Turn the impeller counter-clockwise to release the impeller.
7.
Remove debris from around the shaft and on or under the impeller.
8.
Reattach volute and reassemble.
DO NOT remove countersunk screws holding seal plate to stator housing or warranty will be void.