PR33/DPZ-L
30 / 63
5. Description of funvtions
5.1. Compressed air port
The maximum distance between the compressed air port and the location of the
strapping unit should not exceed 5 m.
In no case it is allowed to run the tool without oil being in the
lubricator of the maintenance unit, as this would immediately
destroy the compressed air motor.
No warranty in this case!
It is recommended that the maintenance unit comprising 2 air outputs and made by the
TITAN
company is used.
5.2. Checking machines and tools before commissioning
Before any new application it is required that the units and their attachments are
checked for damage and completeness. Hoses
– air supply for firm seat. Exclusively
use original TITAN spare parts (also see section 3).
5.3. Commissioning
Connect hand-held units PR 33 and DPZ-L to the compressed air network
(max. air pressure 6 bar).
Motor and compressed air cylinders are lubricated by the oil mist of the compressed
air. Faultlessly prepared compressed air is therefore a prerequisite for a problem-free
operation of the units. This can only be met by a fun
ctionally safe 3/8“ maintenance unit
comprising water separator, pressure reducing valve including pressure gauge and
oiler.
The oiler must discharge sufficient oil, approx. 1 drop per strapping. The length of the
hose should not exceed
5 m
. The inner diameter of the hose should as a minimum be
8 mm. Attention should be paid that the hose does not form loops in which oil could be
collected.
Choice of the lubricating oil: resin- and acid-free lubricating oil whose viscosity is
2-4° E at 50°.
Max. operating pressure 6 bar.
Attention! Risk of tearing strap! The strap can tear when the
operating pressure of 6.5 bar is exceeded. Tearing strap can result
in injuries to the operator.
H365 EU 24/12
Summary of Contents for DPZ-L
Page 14: ...PR33 DPZ L 14 63 8 Konformit tserkl rungen H365 EU 39 12...
Page 15: ...PR33 DPZ L 15 63 H365 EU 24 12...
Page 34: ...PR33 DPZ L 34 63 8 Declarations of conformity of the machinery H365 EU 39 12...
Page 35: ...PR33 DPZ L 35 63 H365 EU 07 10 H365 EU 24 12...
Page 54: ...PR33 DPZ L 54 63 8 D claration de conformit H365 EU 39 12...
Page 55: ...PR33 DPZ L 55 63 H365 EU 24 12...