22
© Titan Tool Inc. All rights reserved.
Fluid Section assembly
1
2
30
4
3
5
7
6
8
11
12
14
15
16
17
18
19
20
21
22
23
13
10
9
24
25
26
27
29
28
42
43
31 32
33 34
35
36
38
37
39
40
41
Install upper packing
with raised lip and
o-ring facing down.
O-Ring
Raised Lip
NOTE: When using “HOT” solvents, replace
Viton o-ring (item 36) with optional
PTFE
o-ring
(P/N 700-897). Install with o-ring tool (P/N 700-890).
Install lower packing with
the side that has the o-ring
closest to the top of the
packing facing up.
Closer
Top