19
CLEANUP / SERVICING
ELITE 4500
6.6
CLEANING AIRLESS SPRAY GUN
i
Clean the spray gun after each use.
1. Rinse airless spray gun with an appropriate cleaning agent.
2. Clean tip thoroughly with appropriate cleaning agent so
that no coating material residue remains.
3. Thoroughly clean the outside of the airless spray gun.
INTAKE FILTER IN AIRLESS SPRAY GUN (FIG. 14)
1. Unclip the top of the trigger guard (1) from the gun head.
2. Using the bottom of the trigger guard as a wrench, loosen
and remove the handle assembly (2) from the gun head.
3. Pull the old filter (3) out of the gun head. Clean or replace.
4. Slide the new filter, tapered end first, into the gun head.
5. Thread the handle assembly into the gun head. Tighten
with the trigger wrench.
6. Snap the trigger guard back onto the gun head.
1
2
3
7
SERVICING
7.1
GENERAL SERVICING
i
We strongly recommend having an annual check
carried out by technicians for safety reasons.
Please observe all the applicable national
regulations.
MINIMUM CHECK BEFORE EVERY STARTUP:
1. Check the high-pressure hose and spray gun connections.
CHECK AT PERIODICAL INTERVALS:
1. Check inlet and outlet valve according wear. Clean it and
replace worn out parts.
2. Check all filter inserts (spray gun, suction system and
pump filter) clean it and replace if necessary.
7.2
HIGH-PRESSURE HOSE
Inspect the high-pressure hose visually for any notches or
bulges, in particular at the transition in the fittings. It must be
possible to turn the union nuts freely. A conductivity of less
than 1 MΩ must exist across the entire length.
Attention
Have all the electric tests carried by an Authorized
Titan Service Center.
i
The risk of damage rises with the age of the high-
pressure hose.
Titan recommends replacing high-pressure
hoses after 6 years.