background image

• Power cord must be connected to a grounded circuit

(electric models only).

• Always flush unit into a separate metal container, at low

pump pressure, with spray tip removed.  Hold gun firmly
against side of container to ground container and prevent
static sparks.

• Follow the material and solvent manufacturer's warnings

and instructions.

• Use extreme caution when using materials with a

flashpoint below 70° F (21° C). Flashpoint is the
temperature that a fluid can produce enough vapors to
ignite.

• Plastic can cause static sparks.  Never hang plastic to

enclose a spray area.  Do not use plastic drop cloths
when spraying flammable materials.

• Use lowest possible pressure to flush equipment.

GAS ENGINE (WHERE APPLICABLE)

Always place pump outside of structure in fresh air.  Keep all
solvents away from the engine exhaust.  Never fill fuel tank
with a running or hot engine.  Hot surface can ignite spilled
fuel.  Always attach ground wire from pump unit to a grounded
object, such as a metal water pipe.  Refer to engine owner’s
manual for complete safety information.

HAZARD: EXPLOSION HAZARD DUE TO INCOMPATIBLE

MATERIALS - Will cause severe injury or
property damage.

PREVENTION:

• Do not use materials containing bleach or chlorine.
• Do not use halogenated hydrocarbon solvents such as

mildewcide, methylene chloride and 1,1,1 -
trichloroethane.  They are not compatible with aluminum.

• Contact your coating supplier about the compatibility of

material with aluminum.  

HAZARD: HAZARDOUS VAPORS -  Paints, solvents,

insecticides, and other materials can be
harmful if inhaled or come in contact with the
body. Vapors can cause severe nausea,
fainting, or poisoning.

PREVENTION:

• Use a respirator or mask if vapors can be inhaled.  Read

all instructions supplied with the mask to be sure it will
provide the necessary protection. 

• Wear protective eyewear.
• Wear protective clothing as required by coating

manufacturer.

HAZARD: GENERAL - This product can cause severe

injury or property damage.

PREVENTION:

• Read all instructions and safety precautions before

operating equipment.

• Always disconnect the motor from the power supply

before working on the equipment (electric models only).

• Follow all appropriate local, state, and national codes

governing ventilation, fire prevention, and operation. 

• The United States Government Safety Standards have

been adopted under the Occupational Safety and Health
Act (OSHA).  These standards, particularly part 1910 of
the General Standards and part 1926 of the Construction
Standards should be consulted.

• Use only manufacturer authorized parts.  User assumes

all risks and liabilities when using parts that do not meet
the minimum specifications and safety devices of the
pump manufacturer.

• Before each use, check all  hoses for cuts, leaks,

abrasion or bulging of cover.  Check for damage or
movement of couplings. Immediately replace the hose if
any of these conditions exist.  Never repair a paint hose.
Replace it with another grounded high-pressure hose.

• Do not spray outdoors on windy days.
• Wear clothing to keep paint off skin and hair.

Grounding Instructions

Electric models must be grounded.  In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
This product is equipped with a cord having a grounding wire
with an appropriate grounding plug.  The plug must be
plugged into an outlet that is properly installed and grounded
in accordance with all local codes and ordinances.

DANGER

— Improper installation of the grounding plug can

result in a risk of electric shock.  If repair or replacement of the
cord or plug is necessary, do not connect the green grounding
wire to either flat blade terminal. The wire with insulation
having a green outer surface with or without yellow stripes is
the grounding wire and must be connected to the grounding
pin.

Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood, or if you
are in doubt as to whether the product is properly grounded.
Do not modify the plug provided.  If the plug will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
This product is rated more than 15 amperes and is for use on
a circuit having a nominal rating of 120 volts, or the product is
for use on a circuit having a nominal rating more than 120
volts, and is factory-equipped with a specific electric cord and
plug to permit connection to a proper electric circuit.  Make
sure that the product is connected to an outlet having the
same configuration as the plug.  No adapter should be used
with this product.  If the product must be reconnected for use
on a different type of electric circuit, the reconnection should
be made by qualified service personnel.

Use only a 3-wire extension cord that has a 3-blade
grounding plug and a 3-slot receptacle that will accept the
plug on the product.  Make sure your extension cord is in
good condition.  When using an extension cord, be sure
to use one heavy enough to carry the current your
product will draw.  An undersized cord will cause a drop
in line voltage resulting in loss of power and overheating.
For lengths less than 50 feet, No. 12 AWG extension cords
should be used.  If an extension cord is to be used
outdoors, it must be marked with the suffix W-A after the
cord type designation.  For example, a designation of
SJTW-A would indicate that the cord would be appropriate
for outdoor use.

CAUTION

© Titan Tool Inc.  All rights reserved.

3

Summary of Contents for PowrTwin 8900XLT

Page 1: ...contains important warnings and instructions Please read and retain for reference Model Number Gas Bare 449 305 DC Electric Bare 449 310 Gas Complete 449 315 Gas Electric Complete 449 320 PowrTwin 89...

Page 2: ...llow body to touch a leak in the fluid hose NEVER put your hand in front of the gun Gloves will not provide protection against an injection injury ALWAYS lock the gun trigger shut the pump off and rel...

Page 3: ...ns and safety devices of the pump manufacturer Before each use check all hoses for cuts leaks abrasion or bulging of cover Check for damage or movement of couplings Immediately replace the hose if any...

Page 4: ...DO NOT use this equipment to spray water or acid Do not lift by cart handle when loading or unloading Warning Labels Your sprayer has the English language warning labels If you require these labels in...

Page 5: ...rks in the refueling area or where gasoline is stored Do not overfill the fuel tank After refueling make sure the tank cap is closed properly and securely Be careful not to spill fuel when refueling S...

Page 6: ...e oil level is determined by the engine manufacturer Refer to the engine manufacturer s service manual supplied with this unit 7 For electric models use a 20 amp service outlet Always locate the elect...

Page 7: ...ays keep the trigger lock on the spray gun in the locked position while preparing the system 1 Place the siphon hose into a container of the appropriate solvent 2 Place the bleed hose into a metal was...

Page 8: ...OFF switch to the ON position 7 Turn the pressure control knob clockwise approximately 1 3 of the way down to increase pressure until the sprayer cycles evenly and paint flows freely from the bleed ho...

Page 9: ...s or any other solvent to clean the sprayer hose or gun Static electricity buildup may result in a fire or explosion in the presence of flammable vapors 1 Follow the Pressure Relief Procedure found in...

Page 10: ...m the following procedure 1 Follow the Pressure Relief Procedure found in the Operation section of this manual 2 Remove the filter cap assembly and spring 3 Pull the filter element with ball straight...

Page 11: ...pstick Hydraulic Filter CAUTION Basic Engine Maintenance gas engine For detailed engine maintenance and technical specifications refer to the separate gasoline engine manual All service to the engine...

Page 12: ...ted at the screw Tighten the screw 6 Place the spring on the brush as shown above Push in and hook the spring clip Repeat this procedure for the other side 7 Reinstall both inspection covers Brush Bru...

Page 13: ...ose and or reduce hose length 1 Replace packing Cause 1 Air in system 2 Dirty gun 3 Needle assembly out of adjustment 4 Broken or chipped seat 1 Worn or broken needle seat 2 Needle assembly out of adj...

Page 14: ...r start machine With pump cycling under pressure touch the hydraulic cylinder and the head to see if cylinder or head gets hotter This will help determine if piston seal is blown or piston nut is brok...

Page 15: ...ler tip orifice size Install pulsation dampener in system or drain existing one Reduce number of guns using pump Remove restrictions in system clean tip screen if filter is used 1 Replace tip 2 Increa...

Page 16: ...assembly 1 x 4 5 1 12 506 276 Convertokit DC electric 115V electric model not shown 1 Parts Lists and Service Instructions Main Assembly 8 9 10 3 11 1 4 3 5 2 6 7 Bleed Hose Assembly with Valve 1 2 3...

Page 17: ...12 590 504 Sleeve 2 13 590 506 Washer 2 14 856 921 Screw 4 15 856 002 Washer 4 16 862 002 Lock washer 2 17 862 428 Screw 2 18 449 052 Spacer 1 19 449 145 Spacer short 1 20 862 411 Nut 1 21 862 001 Fl...

Page 18: ...25 862 001 Flat washer 6 26 862 002 Lock washer 4 27 449 212 Plug 1 28 862 493 Screw HH 2 29 862 496 Tap bolt 1 30 449 982 Shield 1 31 192 228 Elbow 1 32 449 126 Hose clamp 1 33 420 250 Tubing Teflon...

Page 19: ...Flat washer 8 5 459 016 Motor shaft shield 6 860 535 Screw 2 7 506 257 Circuit breaker reset 1 8 506 260 ON OFF switch 1 9 978 350 Motor DC Electric 2 HP 50 60 Hz 115 V 1 Item Part Description Quanti...

Page 20: ...lon thick 1 1 1 5 920 070 Gasket Teflon thin 1 1 1 6 891 193 O ring Teflon 1 1 1 7 180 909 Seat tungsten carbide 1 1 1 8 227 027 Pipe plug 1 1 1 9 930 920 Filter body 1 1 1 10 227 033 Pipe plug 2 2 2...

Page 21: ...1 10 944 010 Valve housing 1 11 944 043 Valve seat 1 12 944 044 Valve seal 1 13 944 013 Valve seat retainer 1 14 944 047 Hex screw 1 15 944 029 Flat washer 1 16 944 046 Spacer 1 944 000 Valve seal kit...

Page 22: ...141 007 O ring 2 3 325 005 Trip spring 2 4 569 016 Ball SS 2 6 441 152 O ring 3 8 441 217 O ring 1 9 858 811 Flex lock nut 1 12 431 032 O ring 2 18 235 027 Piston seal 1 19 235 026 O ring 1 24 235 02...

Page 23: ...ed will hold spool sleeve set 5 in proper place for assembly CAUTION Connecting Pin Retaining Ring 3 Install sleeve retainer 13 followed by snap ring 14 into cylinder head 11 which will hold valve sle...

Page 24: ...her UHMWPE steel 2 5 142 004 Upper packing spring 1 6 144 117 Displacement rod 1 7 138 001 Spring retainer 1 8 142 003 Lower packing spring 1 9 451 085 Outlet valve cage 1 10 138 225 Outlet valve ball...

Page 25: ...0 in lbs 25 ft lbs 4 Insert a new Teflon o ring 3 into the groove of the foot valve housing 20 Lubricate the o ring using oil or grease 5 After soaking the leather packings in oil preferably linseed o...

Page 26: ...941 555 Valve Ball 1 1 3 227 006 Nipple Hex 1 1 808 555 Nipple Hex 1 1 4 227 033 Plug Pipe 1 1 5 970 100 Block Manifold 1 1 6 814 004 Nipple Hex 1 1 Multiple Gun Add On Manifold Assemblies 975 212 97...

Page 27: ...e desired For heavier viscosity materials larger orifice tips are preferred Please refer to the chart below The following chart indicates the most common sizes and the appropriate materials to be spra...

Page 28: ...flammables Elles peuvent causer des blessures corporelles ou des dommages mat riels importants PR VENTION Veillez viter toute accumulation de vapeurs inflammables en vous assurant que la zone de pulv...

Page 29: ...curit du gouvernement am ricain sont r gies par la Occupational Safety and Health Act OSHA Il est important de consulter ces normes en particulier la section 1910 sur les normes g n rales et la secti...

Page 30: ...o incendiarse Se pueden producir lesiones graves y da os materiales PARA PREVENIR Debe proveerse un escape y aire fresco para hacer que el aire que est dentro del rea de atomizaci n se mantenga libre...

Page 31: ...erse a conectar para su uso en un circuito el ctrico de otro tipo la reconexi n debe ser realizada por personal de servicio cualificado Utilice nicamente un cable de extensi n de tres hilos que tenga...

Page 32: ...zed Titan sales service outlet All transportation charges including return to the factory if necessary are to be borne and prepaid by the End User Repaired or replaced equipment will be returned to th...

Reviews: