120V High Amperage Digital Humidity Controller

 

 

• Warnings and Cautions 

 

• Factory Settings 

 

• Eos

® 

120V High Amperage Digital Humidity Controller Overview 

 

• Instructions for Operation 

 

• Error Codes 

 

• Controller Specifications 

 

• Controller Diagrams 

 

• Installation Options 

 

• Installation Example 

 

• Warranty Information 

 

• Service & Repair Program 
 

Warnings & Cautions

 

 

• Read all instructions before operating controller. 

 

• Do not put your controller in an area where it can get wet or sprayed. 

 

• Mount your controller securely to the wall. 

 

• When using “bug bombs” in area, cover controller and sensor completely to avoid corrosion. 

 

• There are no serviceable parts in controller. Do not attempt to repair the unit. 

 

• Breaking tamper proof seal will void your warranty. 

 

• Do not put paper clips, tools, etc. into unit. Possible electrocution may occur. 

 

• Plug controller into surge protector to avoid potential damage to the unit. 

 

• Confirm that your power source is 120 Volts/20 Amps prior to plugging controller into outlet. 

 

• Check that all equipment that will be activated by this controller is the proper voltage. 

 

• Verify that the equipment you are controlling does not exceed a total of 20 amps. 

 

• This controller is designed for “inside use” only. 

 

• Use caution if operating controller in extremely humid environments (90% rH and above). 

 

• Do not use controller for purposes other than the unit was designed to function. 

 

• Use controller within defined environmental specifications. 

 

• Ask your Dealer for tips and techniques regarding the use of this controller. 

 

• Be conscientious when disposing of any products. 

 

2

 

Summary of Contents for EOS 702603

Page 1: ...EOS 120V High Amperage Digital Humidity Controller Instruction Manual Part 702603 www titancontrols net...

Page 2: ...Breaking tamper proof seal will void your warranty Do not put paper clips tools etc into unit Possible electrocution may occur Plug controller into surge protector to avoid potential damage to the un...

Page 3: ...Point Press each knob and turn to set the Day and Night humidity press again to confirm the setting Humidity Dead Band hysteresis 5 rH For example when using Dehumidify if the set point is 45 rH and t...

Page 4: ...er s max amperage rating 20 A Controller Specifications Max Amp 20 amps 120V 60Hz Sensor Cord Length 15 ft Humidity Range 5 90 rH Humidity Accuracy 3 rH Humidity Dead Band Hysteresis 5 rH Weight 2 1lb...

Page 5: ...Installation Options Option 1 Secure the unit to a wall Option 2 Screw the controller to the grow tent tube with a U bolt Installation Example 5 Remote Sensor 120 Volt 120V 20Amps Circuit...

Page 6: ...Controls Monetary refunds of the warranty will not be given The Buyer assumes all responsibility regarding the use installation of this controller All warranty service is provided through the factory...

Page 7: ...__________________________________ Shipping address will be given when the RMA is issued WARRANTY SERVICE Please read warranty information first If after reviewing the troubleshooting tips the unit wi...

Page 8: ...______________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ___...

Reviews: