TIS RLY-8CH-16A Installation Manual Download Page 9

RELAY 8 CHANNELS 16 AMPS

INSTALLATION MANUAL

MODEL: RLY-8CH-16A

TIS CONTROL LIMITED

RM 1502-p9 Easey CommBldg

253-261 Hennessy Rd Wanchai

Hong Kong

TEXAS INTELLIGENT SYSTEM LLC

SUITE# 610. 860 NORTH DOROTHY DR 

RICHARDSON

TX 75081.USA

Copyright © 2020 TIS, All Rights Reserved

TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the 

United States of America. This company takes TIS Control Ltd. in other 

countries. All of the Specifications are subject to change without notice.

w w w . t i s c o n t r o l . c o m

PAIRING

 (MANUAL PROGRAMMING)

To program the curtain to any wall panel, 

press  and  hold  the  CH  (shutter-Open) 

button for 6 seconds. The LED indicator 

of the pressed button will start blinking, 

5

1

2

3

4

5

6

7

8

1

2

TIS-BUS

3

4

5

6

7

8

PRG

1
0

0

0

1

1

0

1

0

1

0

1

0

1

0

1

GND D-

D+ +24V

RLY-8CH-16A

WARNING! HIGH VOLTAGE!

!

6”

Short press on any button on the Luna, 

Mars, Terre or others wall panels. 

6

TER-4G

45mm

25mm

TER-4G

D-

24V

GND

D+

45mm

221

227A

12EM4

227A

12EM4

TER-4G-A

45mm

25mm

45mm

TER-4G-A

             ADD-3R-5A

ADD-3R-5A

50mm

24mm

54mm

PANEL ADDITION

3 Output Relay 5 Amp
Model : ADD-3R-5A
TIS BUS Input : 45-75mA/24V DC
Output Current : 3A220VAC

COM OUT3 OUT2 OUT1 COM

ww

w

.tis

smar

thome.com

D-

+24V

GND

D+

Test the button on the panel by short 

pressing for open/stop. Do the same to 

program the Close channel with another 

button.

7

TER-4G

45mm

25mm

TER-4G

D-

24V

GND

D+

45mm

221

227A

12EM4

227A

12EM4

TER-4G-A

45mm

25mm

45mm

TER-4G-A

             ADD-3R-5A

ADD-3R-5A

50mm

24mm

54mm

PANEL ADDITION

3 Output Relay 5 Amp
Model : ADD-3R-5A
TIS BUS Input : 45-75mA/24V DC
Output Current : 3A220VAC

COM OUT3 OUT2 OUT1 COM

ww

w

.tis

smar

thome.com

D-

+24V

GND

D+

Open

Close

1

2

3

4

5

6

7

8

1

2

TIS-BUS

3

4

5

6

7

8

PRG

1
0

0

0

1

1

0

1

0

1

0

1

0

1

0

1

GND D-

D+ +24V

RLY-8CH-16A

WARNING! HIGH VOLTAGE!

!

To cancel the curtain interlock and return 

to lighting mode, repeat steps 1-3 above.

8

Summary of Contents for RLY-8CH-16A

Page 1: ...ent Max continuous current 20A VAC TIS Bus Number of devices on 1 line Max 64 Bus voltage 12 32 V DC Current consumption Normal 12 mA 24 V DC Current consumption operation 35 mA 24 V DC Protection Rev...

Page 2: ...e a warranty as required by law A hologram warranty seal and product serial number are provided on each device Please send the description of the defect with Product S N to our dealer network Read Ins...

Page 3: ...d to loop the TIS bus cable if 2 DIN Rail modules are connected together from the side bus train terminal 3 GND white orange white brown D white green white blue D blue green 24V brown orange Cat5e co...

Page 4: ...onnect the shutter open wire to the first channel and the shutter close wire to the second channel The shutter neutral wire should be linked to the neutral connection in DB enclosure INSTALLATION STEP...

Page 5: ...m INSTALLATION STEPS MECHANICAL EMERGENCY SWITCH Turn on the power source and then test the loads by short pressing on the device s local override buttons 1 8 6 1 2 3 4 5 6 7 8 1 2 TIS BUS 3 4 5 6 7...

Page 6: ...LY 8CH 16A WARNING HIGH VOLTAGE Short press on any wall lights buttons on the Luna Mars Terre or others panels 2 1 TER 4G 45mm D 24V GND D 45mm 221 227A 12EM4 227A 12EM4 TER 4G A 45mm 45mm ADD 3R 5A A...

Page 7: ...fications are subject to change without notice w w w t i s c o n t r o l c o m Go to floor heater page on any wall panel with the floor heating function and press ON button to turn on the floor heatin...

Page 8: ...ress on the first button and then the second button that you want to combine as curtain control for example CH3 and CH4 2 1 2 3 4 5 6 7 8 1 2 TIS BUS 3 4 5 6 7 8 PRG 1 0 0 0 1 1 0 1 0 1 0 1 0 1 0 1 GN...

Page 9: ...5 1 2 3 4 5 6 7 8 1 2 TIS BUS 3 4 5 6 7 8 PRG 1 0 0 0 1 1 0 1 0 1 0 1 0 1 0 1 GND D D 24V RLY 8CH 16A WARNING HIGH VOLTAGE 6 Short press on any button on the Luna Mars Terre or others wall panels 6 T...

Page 10: ...seconds so the module can get new address Device PRG LED is not Blinking Device not Powered Reason Device is not powered on no TIS BUS 24V supply connected to the device Device Button LED ON but ligh...

Reviews: