Please keep in mind the following:

The device is designed to be powered by a ~230V /

50Hz network;

The device will properly and safely function only if

placed or installed vertically;

Recommended location is about 0.5-1m (1.5-3ft)

from the floor;

The ventilation slots of the device (Fig. 3) must always

remain unobstructed.

The device is switched ON and OFF by pressing the

ON/OFF switch at the bottom of the device.

When starting at room temperature, the device

needs about 20-30 minutes to warm up and reach

full operational capacity;

For best results it is recommended to keep the device

on continuously.

Top vent

Bottom 
vent

ON/OFF 
switch

Fig. 3 Device vents 
and power switch

9. OPERATION

Prior to switching on the device for the first time, ensure that it is approximately at room

temperature to avoid excess condensation on the PC-element, UV lamp and internal electric

components.

10. CARE AND MAINTENANCE

It is recommended to periodically wipe the outside of

the device with a damp cloth. Never use rubbing

alcohol, acetone or other solvents to clean the device.

When the device is turned off for a long time and/or

stored, it must be put in a place with minimum levels of

dust to prevent dust particles from entering through the

air vents as this will detrimentally affect device

performance.

With continuous operation, the device does not require

any maintenance.

6

Summary of Contents for VL20

Page 1: ...VL 20 Krasnoye Pole LLC Version 1 2 June 2020 TIOKRAFT VL20 User Manual PHOTOCATALYTIC AIR CLEANER DISINFECTANT VL20...

Page 2: ...emely dusty environments use in conjunction with a third party air filtering appliance Dear customer Thank you for purchasing the TIOKRAFT VL20 an advanced air purification device designed to silently...

Page 3: ...ventilated rooms Purification of air from organic impurities including pathogenic microflora occurs through their oxidation on the filtering element as a result of which such impurities are completely...

Page 4: ...PRECAUTIONARY MEASURES Use the product indoors only Device vents must remain unobstructed at all times Do not operate the device near a shower bath washbasin or in places where steam may accumulate E...

Page 5: ...ice losing its effectiveness as well as loss of warranty 8 PRINCIPLE OF OPERATION Operation of the device is based on photocatalytic oxidation of organic impurities on a porous glass surface nanocoate...

Page 6: ...t is recommended to keep the device on continuously Top vent Bottom vent ON OFF switch Fig 3 Device vents and power switch 9 OPERATION Prior to switching on the device for the first time ensure that i...

Page 7: ...ction A and remove it by gently pulling in direction B up 3 Flip the bottom cover 180 degrees and place it side by side providing access to the UV lamps 4 Unclip the upper end of the UV lamps and remo...

Page 8: ...nts of SanPiN 2 1 7 2790 10 Sanitary and epidemiological requirements for the management of medical waste Class A or similar 14 WARRANTY This product has been designed manufactured tested and packaged...

Page 9: ...ried out by a qualified technician Unauthorized tampering with the device will void its warranty and may lead to damage to the device 16 CONTACT INFORMATION Krasnoye Pole LLC Moscow region Krasnoarmey...

Page 10: ...L20 BASED ON ACTUAL MICROBIOLOGICAL STUDIES NOTE CFUs in the following diagrams represent Colony Forming Units which are a unit used in microbiology to estimate the number of viable able to multiply b...

Page 11: ...snoye Pole LLC 2020 11 APPENDIX 1 SUGGESTIONS ON PLACING YOUR TIOKRAFT VL20 BASED ON ACTUAL MICROBIOLOGICAL STUDIES CONTINUED Case Study 2 Clinical Lab 16 sq m Test conditions windows and door closed...

Page 12: ...12 APPENDIX 1 SUGGESTIONS ON PLACING YOUR TIOKRAFT VL20 BASED ON ACTUAL MICROBIOLOGICAL STUDIES CONTINUED Case Study 3 Bedroom 20 sq m Test conditions window closed door open at all times BEFORE AFTER...

Reviews: