IP Power Socket 5G10A v2 – LANLIS-002
11
www.tinycontrol.eu
Firmware Upgrade
In the event that there is a new version of the software or special version for application,
it is possible to load such software to the device. This can be done remotely over the ne-
twork using TFTP.
You my upgrade firmware on two way:
1. By dedicate software „LAN Controler Tools” (find controler or put IP and click „Upgrade
Firmware”).
2. By any TFTP client, description below.
Send firmware file by TFTP, you have 5 second (Green LED on RJ45 socket blink) to start
send firmware when modul run after reset (you my casus reset by click button „Save con-
fig and Reboot” in Network configuration or „Reset” button on board or dedicate softwa-
re „LAN Controler Tools”). If start transmision not happen that device start work normal.
If tftp transmision will start than wait about 90 second to finish upload firmware. After
upload device will be reset and start normal. If you want to upload upgrade file chose
„Save config and Reboot” in Network configuration or power OFF and power ON device .
The file must be send in binary mode eg. In Windows XP tftp client
tftp –i 192.168.1.100 put „file_upgrade.bin”.
After successful loading, the device will reboot and will be ready to go.
If you try to send the wrong file get an error message „invalid file”