Tinker & Rasor CI-50 Quick Start Manual Download Page 6

Sponsoring members of NACE International, NACE Foundation 

QMF-570 105-056 

Web: www.tinker-rasor.com 

E-mail: [email protected]

- 6 -

M

ODEL 

CI-50 

Specifications of the Model CI-50 

Maximum 
Current: 

50 Amps 

Maximum 
Voltage: 

120 Volts 

Maximum 
Wattage: 

6000 Watt 

Switching: 

Solid state (no mercury relays) 

ON 

(Closed) 

Cycles: 

0.1 sec to 99.9 sec (Programmable) 

OFF 

(Open) 

Cycles: 

0.1 sec to 99.9 sec (Programmable) 

Battery Size: 

AA size 

Battery Type: 

Alkaline 

Battery Volts: 

(4) 1.5v AA

Cable Size: 

10 AWG (6.0 mm

2

Cable Type: 

Stranded copper, PVC jacketed (Black) 

Cable Length: 

6’ (1.83m) 

Cable Clamp: 

(2) Copper, 75A rated, 0.75” (19 mm) Jaw Opening, 3.00” (76.2
mm) length

Case Dimension:  9.25" x 7.12" x 4.12" (23.5 x 18.1 x 10.5 cm) 
Case Type: 

Tough, thermo-resin plastic (Pelican® type) 

Case Info: 

Closing and locking lid, with carrying handle 

Weight: 

4 lbs (1.81kg) 

CORROSION MITIGATION INSTRUMENTATION 

2828 FM 758, NEW BRAUNFELS, TX 78130 TEL: (830) 253-5621 

Summary of Contents for CI-50

Page 1: ...and duration of the spike the solid state circuitry of the CI 50 and most other current interrupters made today can become significantly damaged It is recommended that an oscilloscope be connected to...

Page 2: ...on for guidance in the type of training necessary to use this instrument properly Programming the CI 50 The Model CI 50 is capable of interrupt cycles of 0 1 sec Closed Seconds On and Open Seconds Off...

Page 3: ...s be turned Off Power toggle switch to Off down when making or breaking connections Connecting the Model CI 50 is done using the supplied cable A single plug in type connector on the end of the cable...

Page 4: ...l CI 50 is a normally Open Off instrument This means that when not in operation or when the power is turned off the circuit through the instrument is Open Off When a program begins the program always...

Page 5: ...he instrument cannot be programmed The Program button will not work until the Display is turned off by again pressing the View Program button or by automatically shutting off Once the Display is off t...

Page 6: ...en Cycles 0 1 sec to 99 9 sec Programmable Battery Size AA size Battery Type Alkaline Battery Volts 4 1 5v AA Cable Size 10 AWG 6 0 mm2 Cable Type Stranded copper PVC jacketed Black Cable Length 6 1 8...

Page 7: ...This step becomes especially important when the DC output of the rectifier is 50 or more of the maximum current the interrupter can handle In the case of the CI 50 which is a 50 Amp max instrument a...