background image

3. The “Self-Test” Cycle. When the unit is turned on, the motor will begin to run. The red indicator light will illuminate for

approximately 30 seconds. The “self-test” lasts for approximately 30 seconds. The unit is then ready for installation.

Note:

See “LED Performance Indicator Lights” section below for an explanation of the LED lights. See the “Timken M-Power

Product Specifications” (page 1) for cycle times and lubricant discharge schedule.
4. The M-Power outlet is R 

1

4

". A reducing fitting may be needed.

5. A brass support adapter must be used on all new M-Power installations where the units are 

directly mounted on the equipment.

LED PERFORMANCE INDICATOR LIGHTS

Description

Frequency

Status

Green Flashing

every 15 sec.

Functioning

Red Flashing

every 8 sec.

Malfunction/high pressure warning

Green/Red Flashing

every 3 sec.

Empty cartridge, needs change-out

Continuous Red

Lubricant discharging

Safety Warnings

In addition to observing warnings on the product and in the operating instructions, be sure to observe the 
following precautions for the use, handling and storage of this device. 

Warning: Proper maintenance and 

handling practices are critical. Failure to follow installation instructions and to maintain proper lubrication
can result in equipment failure, creating a risk of serious bodily harm.

• Retain the product’s safety and operating instructions for future reference. Follow all operating and usage

instructions. Consult the latest material safety data sheet (MSDS) for any lubricant before using, handling or
storing this device.

• Do not remove or open the M-Power device when in operation. All M-Power devices utilize pressure to deliver lubricant to

the application. Removing the device while the contents are under pressure can cause damage to the unit and may result in
severe bodily injury.

• Ensure that the unit has a free path to discharge its lubricant and is not subject to excessive heat. 
• Do not use this product near heaters, radiators, furnaces or other pieces of equipment that may produce sparks, flames, or

high heat. 

• Electromechanical units contain a manufacturer supplied battery pack. Do not attempt to recharge the battery pack, disas-

semble it, immerse it in water or dispose of it in fire. Do not attempt to replace the batteries with any other than replacement
battery packs available from Timken.

• Do not take apart any gas-pressurized unit. Do not take apart any electromechanical device except for replacement of the

battery pack or lubricant refill pack. Do not crush, puncture or incinerate the battery pack or short the metal contacts. 
In addition, do not attempt to open or service the battery pack or lubricant refill packs as doing so may release harmful
chemicals.

• Only use Timken-certified attachments and accessories to connect the M-Power device to the equipment application.

Failure to do so may damage the device and the equipment and may result in bodily injury or damage to the equipment.

• Always check the suitability of any lubricant with the manufacturer of the equipment to be lubricated prior to use. A wide

variety of lubricant oils and greases are available for this secure-lube device depending on the equipment to be lubricated.

• Avoid direct contact of lubricant with skin. Do not swallow or ingest the lubricant. If ingested or swallowed, call a physician

or Poison Control center for most current instructions. If professional advice is not available, do not induce vomiting.

• “Empty” devices retain some lubricant in liquid and/or vapor form. Do not pressurize, mechanically modify or expose used

devices to heat, flame or static electricity. They may cause injury or death. Do not attempt to clean or refill the devices
because the lubricant is difficult to remove. “Empty” devices should be disposed of in an environmentally safe manner, in
accordance with governmental regulations.

The Timken Company
www.timken.com

©2003 The Timken Company
Printed in USA
999-10597

Reviews: