1
1. General Information
These instructions should be read carefully before installation and retained
for further reference and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the
cylinder/pipe thermostat is switched off and the circuit supply fuses
are removed or the circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used
for the installation of this cylinder/pipe thermostat and install
in accordance with the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this cylinder/pipe
thermostat is fitted does not exceed the rating of the circuit cable,
fuse or circuit breaker.
• To clean use a clean dry cloth only. Do not use any liquid cleaners.
3. Technical Specifications
• Operating Voltage:
230V AC 50 Hz
• Switch Rating:
16A Resistive, 3kW
• Switch Type:
Single pole, double throw (SPDT)
• Operating Temperature Range: 0°C to +55°C
• Set Temperature Range:
+40°C to +80°C
• CE Compliant
• Dimensions:
H=105mm, W=38mm, D=56mm