background image

15

Display showing 2hr boost 

periods with On flashing 

after the boost setting 

times out

Display showing normal 

operation when boosts  

are cancelled

The Boost button 

surrounds will 

remain illuminated 

whilst active

Boost Function 

• The boost options are 1 hour, 2 hours, 3 hours and 0 hours to cancel.
• Press the Boost button once for 1 hour, the display light will illuminate 

as well as the Boost button surround. While setting, and during  
the boost period, the On flashes ON and OFF.

• A second press of the Boost button will increase the timed period to 

2 hours, a third press for 3 hours and a fourth press for 0 hours, which will 
cancel the boost timed period and return you to normal operation.

• The boost setting will time out after 15 seconds, and the display light will 

turn OFF. The Boost button surround will remain illuminated whilst active.

2 presses of the 

Boost button for 

2 hours

3 presses of the 

Boost button for 

3 hours

4 presses of the Boost 

button to either channel for 

0 hours to cancel the boost 

timed period

On will flash ON and OFF 
whilst setting, and during the 
boost period

The display light 
will illuminate and 
1hr SET will appear 
on the screen

Press the Boost button for either,  
or both the, heating and hot water.  
The button surrounds will illuminate

Summary of Contents for TRT036N

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 7 Day Digital Programmer 2 Channel Surface Mount Model TRT036N...

Page 2: ...cuit breaker To clean use a clean dry cloth only Do not use any liquid cleaners 3 Technical Specifications 230V AC 50 Hz This thermostat is of Class ll Construction and must not be earthed Switch Rati...

Page 3: ...am pm or 24hr clock timer display illuminated on setting The heating symbol will show when heat is demanded for both channels Flip down cover conceals setting buttons Advance to next Programme ON OFF...

Page 4: ...pply and load cables through the opening of the wall plate Allow sufficient excess cable to wire up the unit but not too much to make it difficult to close the unit to the wall plate 5 5 Fix the wall...

Page 5: ...4 TRT036N Wall Plate Alternate mounting holes Wall plate retaining screws Retaining tabs Mounting holes Loop terminal...

Page 6: ...nection Diagram Connect the 230V 50Hz mains supply and load cables to the terminal block which are marked as follows Note Check boiler instructions before connecting 230V 50Hz Mains Supply Live Supply...

Page 7: ...he DIP switch positions You can set the TRT036N to run a Pumped or Gravity system It is important to check which system you have before setting the DIP switches and operation This can also be set usin...

Page 8: ...ollowed by the 12hr clock format screen After 1 minute the screen will time out showing a default time of 12 00AM There are 3 timed controlled periods per day and the default Programmes are as follows...

Page 9: ...rm 9 6 The year will flash use the Up Down arrow buttons to alter the year and press the Select button once to confirm 12Hr AM PM format Use the Up Down arrow buttons to change the time format 24Hr fo...

Page 10: ...onfirm and exit Use the Up Down arrow buttons to change the month The month will flash Use the Select button to confirm Use the Up Down arrow buttons to change the day The day will flash Use the Selec...

Page 11: ...tailed further in the instructions read the instructions in full before you begin The following steps use the individual 7 day Programming as an example The steps for weekday weekend 5 2 Programming a...

Page 12: ...the minutes and press the Select button once to confirm 10 8 The P2 ON Programme 2 ON hour will flash Follow steps 10 3 to 10 6 for P2 Programme 2 ON and OFF and also P3 Programme 3 ON and OFF 10 9 Pr...

Page 13: ...ill need to be Programmed unwanted times need to be entered as the same time i e P2 ON 7 00AM P2 OFF 7 00AM P3 ON 7 00AM P3 OFF 7 00AM Unwanted days of the week need to be entered as the same time i e...

Page 14: ...step 10 15 until you have copied the programme to all of the days of the week that are required 10 17 Press the Set button twice to exit the programme entry Copy and the day of the week will flash Us...

Page 15: ...next OFF ON until next programmed OFF Note If no button is pressed it will time out after 60 seconds and return to the mains screen showing day time and output status The display light will also time...

Page 16: ...imed period to 2 hours a third press for 3 hours and a fourth press for 0 hours which will cancel the boost timed period and return you to normal operation The boost setting will time out after 15 sec...

Page 17: ...ton once to confirm and exit or confirm and exit by leaving the screen to time out after 15 seconds Any key press will illuminate the screen also with a 15 second time out after the last button press...

Page 18: ...be displayed in the top right had corner of the screen To cancel the holiday press the Display light Holiday button and hold for 3 seconds The holiday duration and suitcase symbol will disappear Holi...

Page 19: ...purchase and it will be replaced free of charge For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all...

Page 20: ...l csc timeguard com For a product brochure please contact HELPLINE 020 8450 0515 or email helpline timeguard com www timeguard com Qualified Customer Support Co ordinators will be on line to assist in...

Reviews: