1. General Information

These instructions should be read carefully and retained 
for further reference and maintenance. The Timeguard 
range of RCDs, provide protection against fire hazard and 
rapid double pole disconnection from electric shock for the 
appliance connected to it. They fully comply with BS7288 
and BS1363-2 (including updates and amendments).  
They are designed to mount on either a BS4662 recessed 
box or a BS5733 surface mount box (plastic versions only).  
Note: RCD – Residual Current Device.

2. Safety

•  Before installation or maintenance, ensure the mains 

supply to the RCD fused connection unit is switched off 
and the circuit supply fuses are removed or the circuit 
breaker turned off.

•  It is recommended that a qualified electrician is 

consulted or used for the installation of RCD fused 
connection unit and install in accordance with the 
current IEE wiring and Building Regulations.

•  Check that the total load on the circuit including when 

this RCD fused connection unit is fitted does not exceed 
the rating of the circuit cable, fuse or circuit breaker.

•  Electricity can be dangerous, use of an RCD should not 

be regarded as a substitute for basic electrical safety 
precautions.

Summary of Contents for RCD01WAVN

Page 1: ...p e r a t i n g I n s t r u c t i o n s RCD Single Sockets RCD01WAVN RCD Single White Socket Active RCD02WPVN RCD Single White Socket Passive RCD03MAVN RCD Single Metal Socket Active RCD04MPVN RCD Si...

Page 2: ...Device 2 Safety Before installation or maintenance ensure the mains supply to the RCD fused connection unit is switched off and the circuit supply fuses are removed or the circuit breaker turned off...

Page 3: ...ric pollution A warming of the casing during use is normal Do NOT use outside the service conditions For devices having a solid neutral ensure the correct polarity of the incoming supply connections s...

Page 4: ...ed Trip Current 30mA RCD Type Double Pole suitable for 2 and 3 wire applications Breaking Capacity 250A Earth leakage Through Fault Withstand 1500A Operating Temp Range 5 C to 40 C Trip Speed Less tha...

Page 5: ...rsion if set will retain closed contacts if the mains supply is interrupted essential for applications such as freezers The non latching version if set allows the contacts to open if the mains supply...

Page 6: ...5 RCD01WAVN RCD02WPVN Blue Reset button R for RCD01WAVN Grey Reset button R for RCD02WPVN Red Test T button Status indicator shows Red for ON Green for OFF ON OFF Switch...

Page 7: ...2x 3 5mm diameter fixing screws 1x Warning label 1x Instruction manual 1x Metal Surface Box RCD03MAVN RCD04MPVN Blue Reset button R for RCD03MAVN Grey Reset button R for RCD04MPVN Red Test T button St...

Page 8: ...boxes it will be necessary to bend back the upper and lower fixing lugs to enable RCD to be fitted 6 1 Ensure the mains supply is switched off and the circuit supply fuses are removed or the circuit b...

Page 9: ...ust be used on the inside of the back box entries to secure the gland or conduit The gland or conduit must not project into the back box beyond the lock ring a male adapter should be used within the b...

Page 10: ...hould show Green This indicates the RCD had been tripped and power has been disconnected 8 3 RESET Press the Grey Blue Reset button marked R again the status indicator should show Red If all the above...

Page 11: ...sional advice 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your supplier i...

Page 12: ...a product brochure please contact Qualified Customer Support Co ordinators will be on line to assist in resolving your query If you experience problems do not immediately return the unit to the store...

Reviews: