9
• The small arrow on the underside of the sensor indicates the direction
of the main detection area.
• The adjustment knobs located on the sides of the sensor head factory
set to “Walk Test Mode” i.e. LUX set to the ‘Sun’ symbol and the
Time set to the minimum.
• Turn the power to the unit ON. The lamp will immediately illuminate
as the unit goes through its “warm-up” period. After approximately
1 – 2 minutes the lamp will extinguish. Try to remain outside the
detection area during the warm-up period.
• Adjust the sensor to point in the desired direction for best coverage.
• The unit will now operate during daytime as well as at night,
illuminating the lamp for approx. 5 seconds each time.
• Walk across the detection area approx. 2.5 metres from the unit. As you
cross a detection "zone" the lamp will illuminate. Now stand still until
the lamp extinguishes (this should take approx. 5 seconds).
• Start moving again. As you cross each "zone" the lamp will illuminate.
• Repeat the above, walking at various distances and angles to the unit.
This will help you to establish the detection pattern.
• If the detection area is too small for your requirements, try angling the
sensor head up. This will increase the coverage distance. Angling the
head downwards will reduce the range should a smaller coverage area
be required.