background image

14

Note: If you have more than one fob to pair  
(Up to 6 max) then press the fob buttons, one at a 
time, waiting for the lamp to turn ON for 3 seconds 
and back OFF again each time, between presses.  
You cannot pair a 7th fob. If attempted, the lamp 
will flash twice to indicate it has not been paired.

• After the last fob press, wait for approximately  

30 seconds until the lamp flashes twice.  
This will indicate that your fob(s) have successfully 
been paired.

Note: once the lamp has flashed twice, the PIR  
light controller will begin to trigger with motion 
once again.

• Test your fob(s) by pressing the fob button once to 

turn the lamp ON, and once to turn the lamp OFF.  
If you are using more than fobs, you are able  
to turn the lamp ON using one fob, and turn  
the lamp OFF using another.

Summary of Contents for LEDPROFOB RF

Page 1: ...l l a t i o n O p e r a t i n g I n s t r u c t i o n s Dedicated PIR Light Controller c w RF remote control for LEDPRO Floodlights Model LEDPRORFKB Black Model LEDPRORFKWH White Model LEDPROFOB RF R...

Page 2: ...is recommended that a qualified electrician is consulted or used for the installation of this PIR sensor and install in accordance with the current IEE wiring and Building Regulations Check that the...

Page 3: ...LUX Level Adjustment 2 1000 Lux Operating Temperature 20 C to 40 C Standby W 0 5W Manual Override Mode ON OFF operation using RF Remote Fob 6 fobs max Sensor Head Adjustment Pan angle Left right 90 Ti...

Page 4: ...Hz IP44 Rated suitable for restricted external applications CE Compliant Dimensions H x W x D 60 x 38 x 15mm 4 Pack contents 1x LEDPRORFKB WH Dedicated PIR Light Controller c w RF remote control for L...

Page 5: ...ller is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS see diagram B Therefore position the unit so that the light controller looks ACROSS the likely approach...

Page 6: ...isolating switch should be installed to enable the power to be switched ON OFF for maintenance purposes During extreme weather conditions the motion light controller may exhibit unusual behaviour Thi...

Page 7: ...rovided on the PIR ensuring that a cable gland grommet or sealing compound is used to maintain the IP rating 6 5 Terminate the cables into the terminal block ensuring correct polarity is observed and...

Page 8: ...y pushing the plug and socket inside the floodlight together until they lock DO NOT FORCE THE PLUG AND SOCKET WILL ONLY FIT TOGETHER ONE WAY AROUND See Jumper Plug diagram 6 8 Secure the PIR to the fl...

Page 9: ...l block as follows Note The Switch Live terminal is for additional standalone floodlights see section 3 Technical Specifications for maximum switchable loads Any floodlight connected to the L1 switch...

Page 10: ...rds Adjust the light controller to point in the required direction and angle down to limit forward range as required Set the two adjustment controls on the underside of the unit to the following posit...

Page 11: ...peration Auto Mode When walk tests are complete the unit can be set into Auto Mode The TIME ADJUST setting controls how long the unit remains illuminated following activation and after all motion ceas...

Page 12: ...onds for the unit to settle When the ambient light level reaches that required for DUSK adjust the DUSK control a small amount clockwise pausing to try to get the unit to detect and turn the lights un...

Page 13: ...ght controllers coverage preventing detection in unwanted areas mask the PIR light controllers lens using the lens sticker supplied The top section of the lens covers long range detection the bottom c...

Page 14: ...tic Operation Auto Mode before you continue Press the centre button that is located on the bottom of the PIR light controller once do not press and hold for longer than 4 seconds the lamp will flash t...

Page 15: ...n paired After the last fob press wait for approximately 30 seconds until the lamp flashes twice This will indicate that your fob s have successfully been paired Note once the lamp has flashed twice t...

Page 16: ...rase all RF Remote Fobs from the PIR Light Controller Press and hold the centre button located on the bottom of the PIR light controller for approximately 5 seconds The lamp will flash 5 times This in...

Page 17: ...t reason The unit may be suffering from false activation Cover the sensor lens completely with black PVC tape This will prevent the sensor from seeing anything If the unit now switches off after the s...

Page 18: ...will not operate at night Refer to section 8 Setting Up for DUSK control adjustment Unit activates during the daytime Refer to section 8 Setting Up for DUSK control adjustment You may not be allowing...

Page 19: ...ll cases For all eligible replacements where agreed by Timeguard the customer is responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a re...

Page 20: ...For a product brochure please contact Qualified Customer Support Coordinators will be online to assist in resolving your query If you experience problems do not immediately return the unit to the stor...

Reviews: