1
3
• Attach the luminaire to the U
bracket fitted to the wall. You
are able to pre-fit the supplied
fixing screws and washers
to the luminaire before you do
this, the screws will just need to
be loose enough to fit over
the upward facing slots
on the end of the
U bracket. Make sure
the washers are in the
correct order as per the
diagram. When the luminaire is
in place, secure the screws
ensuring not to over-tighten.
• Attach the strain relief to the
luminaire and screw in ensuring
not to over-tighten.
• Terminate the supply cable into the terminal
block (please refer to section 5 connection
diagram) ensuring correct polarity is
observed and that all bare conductors are
sleeved.
• Attach the supplied wall plate to the
luminaire, apply pressure to catches
located on top and bottom, then screw
in on both sides ensuring not to
over-tighten.