background image

2

3. Technical Specifications

• Rated voltage : 3V DC 

• Replaceable battery: CR2032 Battery

• Protection class: Class III

• Transmission range: >5m

• Transmission angle: 30°

• Time ON adjustment: 1m to 30m

• LUX light level adjustment:  

10 Lux to 1000 Lux

• Constant LUX level adjustment:  

Constant light value of  
300 Lux to 1000 Lux

• Standby Time adjustment:  

ON, OFF, 1m to 30m

• Permanent override function:  

ON or OFF for 10 hors

• IP Rating: IP40 

• LED Indicator: Yes

• Working temperature: 0ºC to +40ºC

• RoHS compliant

• CE compliant

• IEC/EN61000-6-1 

IEC/EN61000-6-3

• Dimensions (W x H x D): 110 x 55 x 6mm

All manuals and user guides at all-guides.com

Summary of Contents for IRRDALI

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Infra Red DALI Remote Control Model IRRDALI All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...PDSMCDALI PDFMDALI and PDFMCDALI 2 Safety Do not drop knock or shake the product as rough handling may damage the electronics and void the warranty Do not use harsh chemicals cleaning solvents or str...

Page 3: ...djustment 10 Lux to 1000 Lux Constant LUX level adjustment Constant light value of 300 Lux to 1000 Lux Standby Time adjustment ON OFF 1m to 30m Permanent override function ON or OFF for 10 hors IP Rat...

Page 4: ...OCK or UNLOCK the sensor IR receiver The sensor LED indicator will remain ON for 2 seconds for LOCK status and flash for 2 seconds for UNLOCK status Please UNLOCK the sensor IR receiver before setting...

Page 5: ...remain on for 2 seconds and the sensor IR receiver will automatically LOCK Under TEST mode the IR receiver will automatically lock after a 10 minute duration 4 2 Time Setting Press this button to adju...

Page 6: ...d then use the DIM UP DIM DOWN buttons to change the standby light level setting from minimum 0 to a maximum of 60 The sensor LED indicator will flash when it reaches the minimum 0 or maximum 60 4 6 S...

Page 7: ...to exit Test Mode press the or or buttons 4 9 Dim Adjustment Buttons Press the DIM Up button once and the load comes ON to 10 light level This will increase by 10 for each button press The sensor LED...

Page 8: ...10 hour ON OFF Mode 4 11Teach in Mode Press this button to enter Teach in Mode at the desired ambient light level The sensor LED indicator will flash for 10 seconds while learning the ambient light le...

Page 9: ...nd will return to Semi Auto Mode after the delay time ends and the load turns OFF 5 Battery Replacement Lever out the battery holder located at the bottom of the remote control using a small flat head...

Page 10: ...e replaced free of charge For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all cases For all eligible...

Page 11: ...10 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 12: ...please contact Qualified Customer Support Coordinators will be online to assist in resolving your query If you experience problems do not immediately return the unit to the store Telephone the Timegua...