4. Installation

•  Ensure the mains supply is switched off and the circuit supply  

fuses are removed or the circuit breaker turned off.

•  Connect the incoming 230V 50Hz supply and outgoing load  

cables to the relevant terminals ensuring correct polarity  
is observed and that all bare conductors are sleeved  
(see section 5. Connection Diagram). 

•  A front cable exit cut-out is provided with a pre-installed  

removable cover. 

•  If the front exiting cable cut-out is required:
  1.   Undo the 2 fixing screws and remove the blanking plate  

(you can discard the blanking plate at this stage but keep  
the 2 fixing screws).

  2.  Remove the cable grip from the accessory pack. 
  3.   Using the 2 fixing screws previously removed from the blanking 

plate, secure the load cable to the unit. 

•  Finally secure the unit to the back box with the fixing screws 

provided, forming the cables during installation to avoid any 
entrapment and cable damage.

Boost time 
indicator LEDs

Double  
pole switch

BS 1362  

(1"x 

1

/

4

") 

fuse

Boost button

Summary of Contents for FBT4

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Electronic Boost Timer Fused Spur Model FBT4 2 Hour Boost Timer Model FBT5 4 Hour Boost Timer ...

Page 2: ...EE wiring and Building Regulations Check that the total load on the circuit including when this boost timer is fitted does not exceed the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50 Hz Fused Supplied with BS1362 13A Fuse Switch Rating 13A Resistive 3kW 1000W Incandescent Halogen lighting 500W Fluorescent lighting 200W LED lighting 100W Compact Fluoresc...

Page 3: ...stalled removable cover If the front exiting cable cut out is required 1 Undo the 2 fixing screws and remove the blanking plate you can discard the blanking plate at this stage but keep the 2 fixing screws 2 Remove the cable grip from the accessory pack 3 Using the 2 fixing screws previously removed from the blanking plate secure the load cable to the unit Finally secure the unit to the back box w...

Page 4: ...c Supply Live Brown or Red to L IN Neutral Blue or Black to N IN Load Switch Live Brown or Red to L OUT Neutral Blue or Black to N OUT Supply live terminal Switched neutral terminal load neutral connection Loop terminal for earth continuity Supply neutral terminal Switched live terminal load live connection ...

Page 5: ...Ds will go out sequentially indicating the approximate boost time remaining Example 2 hour boost has been set all LEDs are on After 58 minutes the 2 hour LED will flash for two minutes and then go out indicating 1 hour remaining After a further 28 minutes the 1 hour LED will flash for two minutes and then go out indicating hour remaining After a further 13 minutes the hour LED will flash for two m...

Page 6: ...n also be stopped during this time period by holding down the boost button until all the LEDs are off After the first 15 seconds of activation the boost may be cancelled with a single push of the boost button The Boost periods can only be increased during the first 15 seconds of activation At all other times the boost must be cancelled first and the required boost periods re entered ...

Page 7: ...f purchase and it will be replaced free of charge For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all cases For all eligible replacements where agreed by Timeguard the customer is responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a repl...

Page 8: ...il csc timeguard com For a product brochure please contact HELPLINE 020 8450 0515 or email helpline timeguard com www timeguard com Qualified Customer Support Co ordinators will be on line to assist in resolving your query If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline ...