![Time Gaurd SLB150 Installation & Operation Instructions Download Page 8](http://html1.mh-extra.com/html/time-gaurd/slb150/slb150_installation-and-operation-instructions_1116993008.webp)
SECTION FIVE
TECHNICAL SPECIFICATIONS
Detection Range
Detection Angle
Power Supply
Maximum Switchable Load
(Including fitted lamp)
Lamp Type
Time On Adjustment
Dusk Level Adjustment
Environmental Protection
EC Directives
Up to 12 metres
140º
230 V AC ~ 50Hz
2000W (4 x 500W) Tungsten Halogen
1000W (10 x 100W GLS) Incandescent
SLB/W150 230V Linear Tungsten Halogen 150W max
(R7S cap)
SLB/W500 230V Linear Tungsten Halogen 500W max
(R7S cap)
5 seconds - 5 minutes
Day & night or night only operation
IP44 (suitable for outdoor use)
Conforms to 73/23/EEC, 89/336/EEC
In the event of the cover glass shattering, do not replace with normal household glass.
Contact the helpline for replacement details.
If you experience problems refer to Troubleshooting Guide.
If problems still exist, do not immediately return the unit to store.
Telephone the Timeguard Customer Helpline
020 8450 0515
Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.
MASKING THE SENSOR LENS
To restrict the sensor coverage, preventing detection in unwanted areas, mask the sensor lens
using the masking label provided (see diagram D). For your information, the top section of
the lens covers long range detection, the bottom covers short range. Similarly the left and
right lens sections cover the left and right detection areas respectively. (see diagram E)
MANUAL OVERRIDE MODE
The light can be switched on for longer time periods by use of the Manual Override Mode.
This can be activated at night by using the internal wall switch or circuit breaker.
Switch the internal wall switch/circuit breaker twice (off/on off/on) within 2 seconds. The unit
will now illuminate continuously until dawn or until switched back into Auto Mode.
To switch the unit back into Auto Mode, flick the internal wall switch/circuit breaker once
(off/on) within one second. The unit will return to its Auto mode and will operate as set up
during the walk test period.