WALK TEST PROCEDURE

The sensor will rotate from left to right, and tilt forward or backward. Adjust the sensor to
point in the required direction.

The unit can be set up in daylight or at night.

Set the time adjustment to minimum (fully anti-clockwise).
Turn the power to the unit on. The lamp will illuminate for approximately 30 seconds. This
indicates the unit is wired correctly.
After approximately 30 seconds the light will turn off.
The unit is now in Test Mode.

TEST MODE

The lamp will now illuminate for approximately 5 seconds every time movement is detected.
Walk across the detection area approximately 5 metres from the unit. Each time you are
detected the lamp will illuminate. Now stand still until the lamp extinguishes (this should
take approx. 5 seconds).
Start moving again, when you are detected again, the lamp will illuminate.
Repeat the above, walking at various angles and distances to the unit. This will help you to
establish the detection pattern.

If the detection area is too small for your requirements, try angling the sensor head up. This
will increase the detection area. Angling the head downwards will reduce the detection
area should a smaller coverage be required.

SETTING UP FOR AUTOMATIC OPERATION

When walk tests are complete, the unit can be automatically switched into Automatic Mode.
If you simply cease movement within the detection area for approximately 60 seconds, the
unit will then switch to Automatic Mode.

The TIME setting controls how long the unit remains illuminated following activation and
after all motion ceases. (See diagram C, the time adjustment knob is indicated by the
"Clock" symbol).
The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully
clockwise) is approx. 5 minutes. Set the control to the desired setting between these limits.

The DUSK control determines the level of darkness required for the unit to start operating.
The setting is best achieved by the procedure below:

Set the DUSK control knob fully anti clockwise (See diagram C, the DUSK adjustment knob is
indicated by the "Moon" and "Sun" symbols).
Wait until darkness falls.
When the ambient light level reaches the level of darkness at which you wish the lamp to
become operative (i.e.: at dusk) SLOWLY rotate the control in a clockwise direction until a
point is reached where the lamp illuminates. Leave the control set at this point.

At this position the unit should become operative at approximately the same level of
darkness each evening. Observe the operation of the unit. If the unit is starting to operate
too early (i.e.: when it is quite light) adjust the control slightly anti-clockwise.  If the unit
starts to operate too late (i.e.: when it is very dark). Adjust the control slightly clockwise.
Continue to adjust until the unit operates as desired.

SECTION FOUR

OPERATION AND TESTING

Summary of Contents for SLB150

Page 1: ...O P E R A T I N G I N S T R U C T I O N S 5 0 0 W P I R H A L O G E N F L O O D L I G H T S L B 5 0 0 B l a c k S L W 5 0 0 W h i t e 1 5 0 W P I R H A L O G E N F L O O D L I G H T S L B 1 5 0 B l a c k S L W 1 5 0 W h i t e ...

Page 2: ... TO DAWN ADJUSTABLE In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your supplier with proof of purchase and it will be replaced free of charge Should you encounter any difficulty please contact our helpline on 020 8450 0515 3 YEAR GUARANTEE SLB500 SLW500 500W PIR HALOGEN FLOODLIGHT ...

Page 3: ...ier with proof of purchase and it will be replaced free of charge Should you encounter any difficulty please contact our helpline on 020 8450 0515 3 YEAR GUARANTEE WEATHERPROOF IP44 MANUAL ON OFF OVERRIDE DETECTION ANGLE ADJUSTABLE 140 DETECTION RANGE ADJUSTABLE 12m PIR SWITCHING MAXIMUM 2000w TIME ON ADJUSTABLE 5sec 5min DUSK TO DAWN ADJUSTABLE SLB150 SLW150 150W PIR HALOGEN FLOODLIGHT ...

Page 4: ...d tradesperson or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 2 5m Careful positioning of the sensor will be r...

Page 5: ...he lampholder before use Re attach the front cover do not overtighten the fixing screw Mark the position of the fitting holes from the wall bracket Drill the holes Insert the rawl plugs into the holes Fix the bracket to the wall IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation CONNECTION ...

Page 6: ... Mains Supply Isolation Switch The diagram below also shows the required connections for the addition of slave luminaires When adding slaves be sure not to exceed the maximum switchable load see Technical Specifications ...

Page 7: ...de If you simply cease movement within the detection area for approximately 60 seconds the unit will then switch to Automatic Mode The TIME setting controls how long the unit remains illuminated following activation and after all motion ceases See diagram C the time adjustment knob is indicated by the Clock symbol The minimum time fully anti clockwise is approx 5 seconds whilst the maximum time fu...

Page 8: ... 0515 Qualified Customer Support Co ordinators will be on line to assist in resolving your query MASKING THE SENSOR LENS To restrict the sensor coverage preventing detection in unwanted areas mask the sensor lens using the masking label provided see diagram D For your information the top section of the lens covers long range detection the bottom covers short range Similarly the left and right lens...

Page 9: ...ur property Check that the power is switched ON at the circuit breaker internal wall switch Turn OFF the power to the unit and check the wiring connections as per the diagram see previous section 3 Ensure no connections are loose Check the lamp If the lamp has failed replace Ensure that the lamp is seated correctly in the lampholder The level of ambient light in the area may be too bright to allow...

Page 10: ...Less sensitive More sensitive TOP VIEW 140º SIDE VIEW 12m 2 5m A C B D Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection ...

Page 11: ...te SLB150 150W PIR Halogen Floodlight Black SLW150 150W PIR Halogen Floodlight White SLB2000 2000W PIR Light Controller Black SLW2000 2000W PIR Light Controller White SLB88 60W PIR Bulkhead Light Black SLW89 60W PIR Bulkhead Light White SLB44 60W PIR Lantern Light Black SLW45 60W PIR Lantern Light White ...

Page 12: ...Helpline 020 8450 0515 For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND or email csc timeguard com ...

Reviews: