www.timberk.com • electric ceiling heater
5
NOTE:
To improve the product quality, the design and technical
specifications of the infrared heater, as well as its delivery set can be
modified by the manufacturer without preliminary notification.
NOTE:
Depending on material and design of ceiling structural elements, the
heater is secured onto appropriate fasteners chosen on basis of the
strength condition. Strength of the ceiling or structural elements, to
which the heater is secured, should be sufficient to endure 5-fold
weight of the heater.
1. Expand the original packaging and carefully remove the heater
2. Remove the mounting kit
3. Collect the installation wall mount holes as shown in Fig. 2
4. Connect the hardware to the instructions shown in Fig. 3, 4, 5
5. Hang the heater on the smooth surface of the wall with the observance
of the distance specified in item 6.1. Make sure that the mounting screws
firmly fastened
6. If necessary, install the heater, bracket, follow the instructions shown on
Fig. 6, 7, 8, 9 and specified in item 6.3
6.1 Safe distances required for installation
1. Never install the unit on the surface of plastic, nylon, cardboard and
other
2. After installing the unit, the distance from the floor should not be less
than 1.8 meters
3. Distance from a wall to a device must be at least of 0.65 meters
4. The distance from the device to a ceiling should be no less than 0.3
meters
5. The distance from the protective grille device to easily flammable (cloth,
paper, plastic and other) and combustible materials must be at least 1.5-2
meters
6. The distance from the device to find the man should be not less than
1 meter
6.2 Installation of the heater using the wall fasteners
Table 2.
On Fig. 2, 3, 4, 5 shows stepwise instructions on assembly and installation
of wall fasteners for infrared heater.
6. INSTALLATION
WARNING!
Mounting of the infrared heater and its connection to the
electric mains should be carried out only by qualified
specialists according to the Electrical Installation
Regulations and Power System Safety Standards.
№
Parts name
Specification
Qty
1
Screw
M6x20
1
2
Bracket set
Aluminum
1
3
Expansion bolt
M6x60
2
4
Hanger
STEEL
1
5
Bolt
M8х60
1
5A
Nut
M8
1
Summary of Contents for TIR HP1 1500
Page 6: ...www timberk com electric ceiling heater 6 Fig 2 Fig 4 Fig 3 Fig 5...
Page 10: ...www timberk com electric ceiling heater 10 Timberk Timberk 220 50 1 2 3 4 5 6 7 8 9 1 2...
Page 11: ...www timberk com 11 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 80 25 26 3 1 2 1...
Page 13: ...www timberk com 13 1 1 1 2 1 3 1 4 1 5 1 5 1 2 6 2 3 2 4 3 4 5 5 6 1 6 6 7 8 9 6 3 6 5 6 1 1 2...
Page 16: ...www timberk com 16 9 1 220 50 2 3 4 16 7 8 2000...
Page 18: ...www timberk com 18 www timberk com 22...
Page 20: ...www timberk com 20 Timberk ID c TIMBERK ID Timberk...
Page 21: ...www timberk com 21 TIMBERK ID TIMBERK 171 21 12 2004 18 5 TIMBERK TIMBERK ID...
Page 23: ...www timberk com 23...
Page 24: ...www timberk com 24...
Page 25: ...www timberk com 25 TIMBERK c 10...
Page 28: ...www timberk com...