background image

5

ENGLISH

9

. CLEANING YOUR ULTRASONIC HUMIDIFIER 

                                

The method of keeping clean:

Using purified water

Cleaning the base of unit, water tank and ultrasonic transducer every week

Always change to use clean water.

Always drain the water tank when not in use.

Clean all parts of the humidifier before storing by wiping with a damp cloth, 

and buffing with a dry cloth.(Except for the electrical control when the unit is 

off, any part of the humidifier may be wiped with a soft damp cloth, and 

buffed with a dry cloth ,ensuring the unit is unplugged.)

The methods of cleaning the connector:

 To clean the dirty surface with a soft brush.

Rinse the transducer with clean water.

The methods of cleaning the base of unit:

Clean the dirty flume with soft cloth

.

 

If there is dirty on the surface of the protective switch of water line, using soft 

brush to clean

.

 Wash the flume with clean water.

ATTENTION!

In order to avoid deformation and erase the working surfaces, leading 
to  reduced  sputtering  or  other  problems,  do  not  use  wire  brushes, 
talcum powder or blades to wipe the transducer.
When strong shocks the water tank can leak.
When the water leaks immediately discontinue operation of the unit 
and contact your dealer.
To maintain the unit in a dry state to remove the water after cleaning 
and be sure to dry the water tank and the enclosure.
Make sure that inside the water tank and the enclosure is left of water.
Before long a pause in the use of the device dry reservoir and surface of 
the device, install the tank in the housing and pack the humidifier 
in a plastic bag and then into the box.
Keep the instrument in a room with low humidity.
Storage device in unseasoned state leads to mold.

www.timberk.com   electric humidifier

6

FILLING TANK WITH WATER

Before filling the tank with clear dispenser tank. If you do not, by turning the 

tank,  spray  drops. Without  the  spray  device  can  not  operate. When  you 

move the humidifier does not grasp the handle of the tank. Necessary to 

hold the damper at the base.
1. Remove the sprayer, and then the water tank from the device.
2. Grasp the handle on the tank and pull it up.
3. Unscrew the tank counterclockwise.
4. Fill the tank with water.
5. Screw the lid on the tank clockwise.
Make a tight lid lock tank. Make sure that the rubber ring is installed on top 

of the tank. Tighten the lid clockwise.
Incomplete implementation of the above measures lead to ingress of air 

into the water tank and as a result of a malfunction.
6. Set the tank and spray on the device.

7.

 OPERATION

Connect the device to the mains. Pre-fill the tank with water.
To turn the unit on, turn knob (8) the right to On.

 (see Fig.1)

Then turn the knob of the intensity output pair (7) clockwise until it stops 

(maximum  capacity).  After  about  half  a  minute  the  device  should  go  for 

maximum performance in moisture.
To control the intensity of the steam turn the knob (7) to the left and right.

(see Fig. 2) Upon fall of water level in the reservoir lower minimum allowed 

the  ultrasound  membrane  of  the  device  cuts  out  automatically. The  red 

detector lights up on the control panel. To continue the device functioning it 

is necessary to fill the reservoir with water in accordance with the paragraph 

6 Filling the reservoir with water.

To turn the unit off, turn knob (8) in the left to Off.

 (see Fig. 2)

8

THE FILTER CARTRIGE

The set of the unit includes a cartridge filter with an ion exchange resin. Upon 

long  use  of  the  humidifier  without  replacement  of  resin  a  white  residue  may 

appear on the unit and objects next to it.

The white residue is calcium and magnesium comprised in the composition of 

ordinary tap water. When the ion exchange resin in the filter expires, they are 

released along with steam and settle on the surrounding objects and surfaces. 

Though these substances are safe for people, in large amounts they may have 

hazardous effect on furniture. By means of an ion exchange filter, installed at the 

bottom of the tank, calcium and magnesium are removed from tap water. At the 

beginning of operation the ion exchange filter can make water tea-colored. This 

doesn t affect safety or operation of the unit.

To replace the filter it is necessary to remove a cap by turning it counterclockwise 

and 

then  remove  the  filter  also  by  turning  it  counterclockwise.  The  new  filter  is 

installed in the reverse order. To purchase an ion exchange filter, please, contact 

the seller.

Summary of Contents for THU UL 06

Page 1: ...Instruction manual Outlook of devices aslo colour scores can be revised without any special advance notices Electronic humidifier 71 THU UL 06 Model...

Page 2: ...nd increase of electrostaticchargeofsyntheticfabrics aswellascarpetsandsyntheticfloor coatings it causes damage of wooden furniture and especially parquet floors itnegativelyaffectstuningofmusicalinst...

Page 3: ...umidifier so that the power cord cannot be stumbled upon Do not use the humidifier in damp rooms Do not allow foreign object to get into the humidifier Do not block the air intake and humidifier s ato...

Page 4: ...To avoid electric shock before you disassemble the unit take off the tank unplug the appliance Do not fill the tank other liquids except for tap water Another of the liquid is harmful to internal comp...

Page 5: ...wise 4 Fillthetankwithwater 5 Screwthelidonthetankclockwise Make a tight lid lock tank Make sure that the rubber ring is installed on top ofthetank Tightenthelidclockwise Incomplete implementation of...

Page 6: ...ountermeasure No malfunction If it is necessary to switch to the intensive mode press the Spraying rate button in the manual setting mode and switch the device to the intensive mode Clean the sprayer...

Page 7: ...Timberk 2 1 40 60 1 2 3 4 5 6 7 8 9 10 11 12 7 7 7 8 9 9 10 10 10 10 11 11 12 www timberk com...

Page 8: ...3 300 220 50 3 5 30 0 136 IPX0 II cIass 269x165x269 1 9 8 www timberk com 5 20 1...

Page 9: ...9 www timberk com 4 1 2 1 2 1 2 3 4 5 6 7 8 9 POWER 10 LOW WATER 360 5 1 1 2 1 3 1 4 1 5 1 1 2 3 4 5 6 7 8 Power ON Low water 8 7 10 9 40...

Page 10: ...10 www timberk com 6 1 2 3 4 5 6 7 8 On 2 7 2 7 2 Low water 8 Off 2 8 9 400 180...

Page 11: ...11 www timberk com 10 2 11 2 2...

Page 12: ...2 28 4 7 495 6044266 7 495 6044266 52161 2 30 2007 51318 14 1 2006 4 51318 14 2 2006 5 7 51317 3 3 2008 51317 3 2 2006 6 7 RU C IL AB71 B 00081 5 07 2012 4 07 2015 10 88000 972 8 637 88 311 OOO 1 1 60...

Page 13: ...13 www timberk com...

Page 14: ...14 www timberk com...

Page 15: ...15 www timberk com Timberk Timberk 1 2 3 1 2 3 c 10 4 RU BY KG KZ UA AK TJ OS CIS...

Page 16: ...www timberk ru 71 www timberk com...

Reviews: