10. TRANSPORTATIOM AND STORAGE
Temperature
requirements*
Humidity
requirements*
We are exploring new technologies and we constantly improving the quality
of our products. That’s why specifications, design and accessories are
subject to change without any specific notice.
* This product must have storage in dry, well-ventilated space of warehouse at the temperature
not lower than -30°
Transportation and
storage
From -30° to +50°
From 15% to 85%
(without a condensate)
The unit must be cleaned regularly to remove dust and dirt from external
surfaces, since it affects its operation efficiency and temperature
parameters of room heating. Prior to preventive operations, switch off
the unit and disconnect it from electric mains, let it cool down, then wipe
its surface by a soft and slightly damp duster. It is not recommended to
use detergents for washing, including materials with abrasive elements.
Prevent damaging the unit by sharp objects, since scratches on a painted
surface may cause rusting.
Rear surface of the convector must also be regularly cleaned from dust and
dirt. For this purpose it is necessary to dismount the unit from the bracket,
and after cleaning it is necessary to return it to the initial position.
Preventive cleaning should be performed regularly to maintain technical
condition of the convector and preserve its external appearance for a long
time.
Upon completion of service life, the fan heater must be disposed in
compliance with regulations, rules and by means, currently in force at a
disposal station. Such information on disposal of the fan heater you can
obtain from a representative of local authorities.
8. MAINTENANCE
9. DISPOSAL
Possible malfunctions and remedies.
If you are not able to remedy a malfunction according to the
recommendations or other malfunctions occur, contact the authorized
service center of Timberk.
11. TROUBLESHOOTING
Malfunction
Cause
Remedy
1. The heater heats poorly
1. The heating element is faulty
1. Contact the authorized service center
of Timberk
2. Low voltage in the electric mains
2. Check voltage in the electric mains
2. The heater does not work
1. No voltage in the electric mains
1. Check presence of voltage in the
electric mains
2. Breakdown of the electric cable
2. Check integrity of the electric cable and
replace it if necessary
3. The automatic circuit breaker of the
electric mains is faulty
3. Check operability of the automatic circuit
breaker of the electric mains and replace
the faulty circuit breaker if necessary
4. Breakdown in the heating element circuit
4. Contact the authorized service center
of Timberk
Summary of Contents for TFH T20FSN.LZ
Page 8: ...www timberk com Electric fan heater 8 TIMBERK TIMBERK 220 50 1 1 2 3 4 5 2...
Page 9: ...6 7 8 9 10 180 11 12 220 50 12 50 10 11 12 13 14 15 www timberk com 9...
Page 11: ...1 2 3 5 4 4 1 2 3 4 5 5 20 5 1 1 2 3 4 5 www timberk com 11...
Page 13: ...1 POWER 2 MODE 3 4 TIMER 5 1 2 3 3 1 2 3 4 5 1 2 30 www timberk com 13...
Page 17: ...Timberk c 10 www timberk com 17...
Page 19: ...www timberk com 19...
Page 20: ...www timberk com...