background image

www.timberk.com • electric convector heater

9

9. Air ionizing function

The convector is equipped with an air ionizer.
9.1. You can switch on and off the air ionizer by means of the ionizer button 

«       ».
9.2. Air ionizer indicator  «       » is illuminated when the air ionizer is switched 

on.
9.3. The air ionizer is a completely independent device and can operate 

even when the unit’s heating mode is off.

10. «RESTART» function

In case of a short-term power outage, the convector will be automatically 

switched on and will operate with the last user settings (except for timer 

settings) after power supply is restored.

11. Switch off the convector

To switch off the convector, press and hold button «       » for 3 seconds.

NOTE:

A small static electric charge may be accumulated on 

metal surfaces of a case in units, equipped with an 

air ionizer.
If your electric main has no grounding circuit or it is 

damaged. In this case there is a small possibility of 

electric shock from static voltage.

IMPORTANT! 

If the unit is operated without a grounding circuit or it 

is damaged, it is not recommended to switch on and 

operate the air ionizer.

8. AIR IONIZER OPERATION PRINCIPLE AND PURPOSE

Table 2

Rated indices

Concentration

n+ (ion/cm3)

Concentration

n- (ion/cm3) 

Unipolarity

coefficient Y

Minimum

permissible

N+>=400

n->=400

0,4=<Y=<1,0

Maximum

permissible

n+<=50000

n-<=50000

The unit must be cleaned regularly to remove dust and dirt from external 

surfaces, since it affects its operation efficiency and temperature 

parameters of room heating. Prior to preventive operations, switch off the 

unit and disconnect it from electric mains, let it cool down, then wipe its 

surface by a soft and slightly damp duster. It is not recommended to use 

detergents for washing, including materials with abrasive elements. Prevent 

damaging the unit by sharp objects, since scratches on a painted surface 

may cause rusting.
Rear surface of the convector must also be regularly cleaned from dust and 

dirt. For this purpose it is necessary to dismount the unit from the bracket, 

and after cleaning it is necessary to return it to the initial position.
Preventive cleaning should be performed regularly to maintain technical 

condition of the convector and preserve its external appearance for a long time.

9. MAINTENANCE

capture these electrons, receiving a negative charge and become negative 

air ions, thus, a high concentration of light negative air ions of oxygen is 

generated in the air.
The Ionizer is designed for sanitation and prevention of different diseases; to 

reduce fatigability, to improve ability to work and immunity; to clean air
from airborne pollutions, allergens and microorganisms; to neutralize harmful 

impact of operating computers, TV sets, office equipment on man; to restore 

biological activity of the air, coming to a room through air conditioners, filters, 

air-ducts; to create a comfortable environment and good mood.
Besides, air ionizers are intended to clean the air from tobacco smoke, smells, 

resins, dust, pollen, plant spores, animal hair, viruses and bacteria. Air ionizers 

will help to preserve your health, prevent infectious diseases, allergies and 

create a comfortable environment at home and/or in the office.
Applied air ionizer complies with the current SanPiN dated 2003. Values of 

rated indices of air ion concentrations and the unipolarity coefficient are given 

in Table 3 (as per SanPiN 2.2.4.1294-03):

For models TEC.PF3 LE... IN

Principle of operation of the ionizer is generally reduced to the fact that under 

high voltage, applied to metal needles with diameter of the point equal to 

5…10 m, there is electron flowing-off  electric efflux. Molecules of air oxygen 

Summary of Contents for TEC.PF3 LE 2000 IN

Page 1: ...TEC PF3 M 1000 IN TEC PF3 M 1500 IN TEC PF3 M 2000 IN TEC PF3 LE 1000 IN TEC PF3 LE 1500 IN TEC PF3 LE 2000 IN Electric convector heater Outlook of devices aslo colour scores can be revised without an...

Page 2: ...ting element cooled down prior to the unit is dismantled and packed for long term storage 5 When the unit is not operated for a long time store it factory packaged in a dry and cool place 6 DO NOT COV...

Page 3: ...electric extenders However if necessary an extender may be used if its parameters comply with the unit s power and if it is not used by other power energy consumers 25 For normal operation of the unit...

Page 4: ...ment and differ from each other by the unit s length at equal height and depth Standard overall height of all units is equal to 400 mm This pattern in forming overall dimensions allows the consumer to...

Page 5: ...owels attach the mounting bracket and fasten adjusting screws thereby securing the bracket on the wall 7 Mount the convector on the bracket by connecting 4 slots on the back part of the convector with...

Page 6: ...eries convectors are equipped with a mechanical thermostat TEC PF3 LE IN series convectors are equipped with a high precision electronic thermostat with a LED display 1 Heating indicator light It is i...

Page 7: ...s connected to electric mains TEC PF3 EL IN series control panel Fig 8 14 3 LED display LED display can show temperature and timer settings 4 Comfort mode indicator It is illuminated when the convecto...

Page 8: ...isplay The convector will automatically maintain temperature within the range 5 C to 7 C switching on and off heating from time to time 5 Set the convector switch off timer function 5 1 When the conve...

Page 9: ...including materials with abrasive elements Prevent damaging the unit by sharp objects since scratches on a painted surface may cause rusting Rear surface of the convector must also be regularly clean...

Page 10: ...dy 1 The heater heats poorly 1 The heating element is faulty 1 Contact the authorized service center of Timberk 2 Low voltage in the electric mains 2 Check voltage in the electric mains 2 The heater d...

Page 11: ...www timberk com 11 imberk Timberk 220 50 1 2 3 4 5 6 1 2...

Page 12: ...www timberk com 12 7 8 9 180 10 11 12 13 14 15 16 17 18 TEC PF3 LE IN 19 20 21 22 23 24 25 26 27 28...

Page 13: ...50 500 1000 1500 6 8 4 4 595 400 69 TEC PF3 M 2000 IN 220 50 800 1200 2000 9 1 5 6 830 400 69 TEC PF3 LE 1000 IN 220 50 400 600 1000 4 5 3 6 460 400 69 TEC PF3 LE 1500 IN 220 50 500 1000 1500 6 8 4 4...

Page 14: ...www timberk com 14 1 2 3 4 5 4 2 5 20 1 1 2 1 3 2 4 1 5 1 6 1 6 5 1 2 3 1 4 5 2 3...

Page 15: ...www timberk com 15 4 5 3 4 5 6 4 7 50 60 5 8 5 9 6 1 2 2 3 4 5 1 220 50 2 3 6...

Page 16: ...imberk com 16 4 10 2000 12 2500 50 10 3 1 5 2 TEC PF3 M IN TEC PF3 LE IN c LED TEC PF3 M IN 7 7 1 2 3 1 heating 2 3 1 2 3 TEC PF3 M IN 1 2 2 1 1 1 2 2 2 2 2 3 1 2 3 3 1 5 30 3 2 max heating heating 4...

Page 17: ...www timberk com 17 5 comfort comfort 6 0 8 10 9 8 3 4 7 12 5 6 2 1 13 11 TEC P F3 LE IN 14 1 2 3 LED 4 5 6 7 8 AF 9 10 up 11 down 12 13 14 1 2 3 TEC PF3 LE IN 1 2 2 1 1 1 2 2 2 2...

Page 18: ...www timberk com 18 2 3 1 2 3 3 1 5 30 1 3 2 24 17 3 3 LED 3 4 LED 3 5 LED 4 4 1 4 2 4 3 LED AF 5 7 5 5 1 LED 0 5 2 1 0 24 LED 5 3 3 5 4 LED 5 5 0 6 6 1 LED 0 6 2 1 0 24 LED 6 3 7 8 8 1 3 LED 3...

Page 19: ...www timberk com 19 8 2 3 9 9 1 9 2 9 3 10 RESTART 11 3 TEC PF3 LE IN 5 10 2003 3 2 2 4 1294 03 2 n 3 n 3 Y N 400 n 400 0 4 Y 1 0 n 50000 n 50000 8...

Page 20: ...www timberk com 20 9 TEC PF3 M 1000 IN TEC PF3 M 1500 IN TEC PF3 M 2000 IN TEC PF3 LE 1000 IN TEC PF3 LE 1500 IN TEC PF3 LE 2000 IN 10 9 10 Timberk 11 1 1 1 Timberk 2 2 2 1 1 2 2 3 3 4 4 Timberk...

Page 21: ...www timberk com 21 Timberk Timberk www btpart ru www timberk com Timberk www btpart ru Timberk www btpart ru...

Page 22: ...www timberk com 22 Timberk c 10...

Page 23: ...www timberk com 23 www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Page 24: ...www timberk com...

Reviews: