16
www.timberk.com
storage water
heater
Water heater operation (for FE1/FE2 series)
1. Switching on
1.1 At first, open one of the hot water outlet valves, then open the cold
water supply valve. The electric water heater will start filling with water.
When water flows from the hot tap freely, it means the water heater is fully
filled with water and you can close the hot water outlet valve.
NOTE:
During normal operation the cold water supply valve must be set
open.
1.2 Plug the power cord into the outlet, at that an indicator light on GFCI
and temperature controller handle lighting will light up.
1.3 Press the temperature controller handle and hold it for a few seconds, at
that indicator lights will start flashing for some time, showing the set water
heating temperature, after that indicator lights will show water heater's
water temperature.
2. Water heating temperature setting
2.1. Water temperature in the water heater can be set within the range +5°C
to +75°C.
2.2. Turning the temperature controller handle clockwise (from min to
max ), you increase the water heating temperature, at that the number of
indicator lights on the control panel increases.
2.3. Turning the temperature controller handle counterclockwise (from
max to min ), you decrease the water heating temperature, at that the
number of indicator lights on the control panel decreases.
2.4. The water heater automatically maintains water temperature. When
water temperature in the water heater reaches the temperature, set by the
user, the heating is automatically switched off, at that heating indicator
light on the control panel lights down. When water temperature in the
water heater drops to a certain level, the heating is automatically switched
off, at that heating indicator light on the control panel lights up.
NOTE:
When setting temperature, having reached the optimal heating
position
(+58° (+/- 2° ), you will hear a sound signal (for some
models).
IMPORTANT!
Water may start dripping from the relief valve hole during
heating. It is impossible to avoid water leakage and you must not
prevent it since valve blocking may cause rupture of the internal
tank (in case of equipment failure).
3. Power mode selection
3.1. Press the thermostat knob several times to select the desired heating
power.
3.2. If you select low heating power then energy save indicators light up, if
you select medium heating power then normal heat indicators light up, if
you select high heating power then energy save and normal heat
indicators light up simultaneously.
3.3. After the heating mode is selected, energy save and normal heat
indicators are on for 10 minutes, then they light down.
4. Switching off
Press the temperature controller handle and hold it for several seconds to
switch off the appliance, at that indicator lights will light down and the
temperature controller handle lighting will stay on.
Summary of Contents for SWHFE130V
Page 32: ...32 www timberk com 2 G1 2 3 4 5 6 7 1 230 2 10A 2 3 1 5 50 3 ...
Page 33: ...33 www timberk com 7 1 2 1 2 10 11 FS2 1 1 2 2 220 1 1 2 2 1 3 3 3 1 9 2 1 3 1 9 FS1 ...
Page 43: ... Timberk Timberk www btpart ru www timberk com Timberk 43 www timberk com ...
Page 44: ...RU Timberk Timberk KZ AK BY OS TJ UA KG CIS c 10 44 www timberk com ...
Page 46: ...46 www timberk com ...
Page 47: ...47 www timberk com ...
Page 48: ...www timberk com ÀÂ71 ...