5.
The water heater is equipped with a temperature
limiter (figure 10)
which cuts off power supply to the
heating element upon water overheating or its
absence in the water heater. If the water heater is
connected to the electrical main, but water does not
heats and the handle lamp does not light then the
temperature limiter was switched off or not switched
on. To reset the water heater to the operating condi-
tion it is necessary to:
-
unplug the water heater from the electrical main
, remove the face panel
cover;
- press the button located in the centre of the temperature limiter placed on the
heating element until it clicks;
- if the button cannot be pressed and there is no click then you should wait until
the temperature limiter cools down to the initial temperature.
Fig
.
10
ATTENTION
!
If these actions have no positive result or the temperature limiter turns
off repeatedly during a short period of time then you should unplug the
water heater from the electrical main, cut off water supply and contact
your local Timberk Authorized Service Centre for a consultation or
repair of the appliance.
ATTENTION
!
If water does not flow then the valve is damaged. In this case you
must not use the heater; it is recommended to call for a service
technician.
7.
Wipe external surfaces of the water heater by a damp cloth with soap
when necessary.
6.
Bear in mind to check serviceability of the pressure safety valve every 14
days. The inspection method is as follows:
-
turn the handle for draining to the upper position until you feel the
change of thread, then water must start flowing out from the valve
opening; after checking the water outflow return the handle to its initial
position.
4. S
chedule maintenance should be performed under strict observance of this
instruction manual and safety precautions.
ENGLISH
10.
TROUBLESHOOTING
All the disorders in operation of the water heater should be fixed as well
as putting of the appliance in long-term storage should be performed
in appropriate service centres. The water heater must be prepared for
long-term inactivity only by specially trained qualified specialists,
because improperly performed repair can result in hazard during water
heater operating.
You can ask the seller for the address of the nearest service centre or
find it on the website
www.timberk.
com.
Table 3
Possible malfunctions and troubleshooting methods
FAILURE
POSSIBLE CAUSES
REMEDIAL PROCEDURE
Indicator lamps do not
light, water does not
heats
Water does not flow
out from the hot water
tap
Water temperature is
too high
Water leakage
Water flows out from
the appliance case
Heating indicator lamp
lights, but water does
not heats
1. Temperature controlling device
is damaged.
2. Temperature limiter was
actuated or not switched on.
3. Temperature limiter is
damaged.
1. Address to a repair specialist, a Timberk
authorized service centre.
2. Switch the temperature limiter on in
accordance with the instruction on its
switching on.
. Address to a repair specialist, a Timberk
authorized service centre.
1. Water supply is cut-off.
2. Water pressure is too low.
3. Cold water supply valve is closed.
Water temperature control system
is damaged.
Seal at the point of pipe connection
is broken.
1. Breaking of inner tank (corrosion)
2. Seal at the point of the heating
element connection is broken.
1. Temperature controlling device
is damaged.
2. Insufficient time for heating.
3. Heating element is broken.
1. Wait until water supply is restored.
2. Switch the water heater on again when
normal water pressure restores.
3. Open the cold water supply valve.
Address to a repair specialist, a Timberk
authorized service centre.
Replace the joint seal.
Address to a repair specialist, a Timberk
authorized service centre.
1. Address to a repair specialist, a Timberk
authorized service centre.
2. Wait until water heats up.
3. Address to a repair specialist, a Timberk
authorized service centre.
9
www.timberk.com
Summary of Contents for SE1 VO Series
Page 15: ... 1 7 2 220 V 10A 1 8 7 1 0 1 0 75 0 75 0 75 2 G1 2 3 4 9 5 6 7 15 www timberk com ...
Page 16: ... 1 220 2 10A 2 3 1 5 50 220 7 SWH SE1 VO 10 3 1 5 1 2 HEATING 8 1 2 2 8 1 16 www timberk com ...
Page 21: ...21 www timberk com RU Timberk Timberk KZ AK BY OS TJ UA KG CIS c 10 ...
Page 22: ... Timberk Timberk www btpart ru www timberk com Timberk 22 www timberk com ...
Page 23: ...23 www timberk com ...
Page 24: ...www timberk com ÀÂ71 ...