1. INTRODUCTION

Prior to use of our products you should 

inspect the equipment for any defects 

which may have occurred during trans-

portation. If this happens, please con-

tact your retailer.

Next, please read these instructions 

which include important user informa-

tion. 

Please contact us if you have any ques-

tions concerning the use of the equip-

ment. Our advisors will provide you 

with any information you require on an 

ongoing basis. 

Please note that if you have questions 

other than those concerning the use of 

our products, you should contact your 

doctor, nurse or physical therapist. 

2. PRODUCT 

DESCRIPTION

The anti-decubitus bubble mattress 

with pump is a set which includes an 

alternating pressure mattress and a 

compressor (air pump). The mattress 

is made of durable PVC with a bubble 

structure; the bubbles are inflated with 

air in alternate cycles by the compres-

sor (air pump). By cyclically changing 

the support points of the person lying 

on the bed, this set minimizes pres-

sure on the parts of the body which are 

most at risk from bedsores and makes 

it possible to avoid or reduce skin dam-

age. The PVC used in the mattress is 

made of a non-toxic and hypoallergenic 

material.

The set includes: 

• 

Soft Wind III alternating pres-

sure pump

• 

Air cell mattress 

• 

Repair kit (patch + glue)

• Spare 

fuse

• Air 

hoses

3. INDICATIONS

Anti-decubitus bubble mattress with 

pump are aids for people at risk of bed-

sores. They are used for people who 

are bedridden for an extended period 

of time, in whom peripheral circulatory 

system disorders occur, and also for in-

dividuals with signs of subcutaneous or 

open skin damage caused by long-term 

pressure. These mattresses are used to 

prevent bedsores and treat stage I (ac-

cording to NPUAP / EPUAP) bedsores. 

The mattress works by cyclically chang-

ing support points of the person lying 

on the bed, minimizing pressure on 

the parts of the body which have the 

greatest risk of bedsores. This improves 

circulation in the tissues of those body 

parts which remain in contact with the 

bed for the longest period. It should 

be noted that the operating principle 

of the mattress described above can-

not eliminate all causes of skin lesions; 

however, it can significantly limit their 

development. 

Contraindications for the use of alter-

nating pressure mattresses are de-

termined by a physician based on a 

physical examination and medical his-

tory. As a general guideline, the mat-

tress should not be used if alternating 

changes of support points cause pain 

and an exacerbation of the patient’s 

condition. 

instrukcja_A5_TGR-Y MB 001-1_pol-ang.indd   14

instrukcja_A5_TGR-Y MB 001-1_pol-ang.indd   14

2016-09-05   18:24:39

2016-09-05   18:24:39

Summary of Contents for TGR-Y MB 001-1

Page 1: ...MATERAC PRZECIWODLE YNOWY Z KOMPRESOREM ANTI DECUBITUS BUBBLE MATTRESS WITH PUMP TGR Y MB 001 1 PL EN instrukcja_A5_TGR Y MB 001 1_pol ang indd I instrukcja_A5_TGR Y MB 001 1_pol ang indd I 2016 09 0...

Page 2: ...instrukcja_A5_TGR Y MB 001 1_pol ang indd II instrukcja_A5_TGR Y MB 001 1_pol ang indd II 2016 09 05 18 24 39 2016 09 05 18 24 39...

Page 3: ...cjonalne i bezpieczne Mamy wieloletnie do wiadczenie w bran y Nasze pro dukty za spraw dystrybutor w trafiaj do szerokie go grona u ytkownik w w Polsce i Europie Jako firma otwieramy si na Pa stwa pot...

Page 4: ...tyaler gicznego materia u Zestaw zawiera pomp zmiennoci nieniow Soft Wind III materac komorowy zestaw naprawczy ata klej zapasowy bezpiecznik przewody powietrzne 3 ZASTOSOWANIE Materac przeciwodle yno...

Page 5: ...zaleca si przykry materac podk adem higie nicznym lub bawe nianym prze ciera d em tak aby zabezpieczy go przed zabrudzeniem KROK 2 Wieszak kompresora nale y otworzy na odpowiedni szeroko i powiesi go...

Page 6: ...NYCH POTRZEB U YTKOWNIKA WYNIKAJ CYCH ZE STANU OG LNEGO I DOLEGLIWO CI TOWARZYSZ CYCH CHOROBIE W TYM CELU NALE Y SKONSULTOWA SI Z LEKARZEM PROWADZ CYM KOMPRESOR PRACUJE T OCZ C POWIETRZE NAPRZE MIENNI...

Page 7: ...ENIA WIESZAK KOMPRESORA POMPA 220V 50HZ SILNIK W CZNIK 2 W CZNIK 1 SCHEMAT KOMPRESORA SOFT WIND III SCHEMAT ELEKTRYCZNY instrukcja_A5_TGR Y MB 001 1_pol ang indd 5 instrukcja_A5_TGR Y MB 001 1_pol ang...

Page 8: ...TRZECIE NIE POWINNY SIADA NA MATERACU MATERAC MO NA STOSOWA TYLKO NA P ASKICH PO WIERZCHNIACH NALE Y CHRONI MATERAC PRZED OSTRYMI PRZEDMIOTAMI ORAZ NIE NALE Y K A GO BEZPO REDNIO NA SPR YNACH I STELA...

Page 9: ...TNIEJE RY ZYKO USZKODZENIA MATERACA NIE NALE Y DOKONYWA SAMODZIELNYCH NAPRAW CZY PRZER BEK KONSTRUKCYJNYCH ZALECAMY U YWANIE TYLKO ORYGINALNYCH CZ CI ZA MIENNYCH POCHODZ CYCH OD WYTW RCY W TYM CELU SK...

Page 10: ...jduj cymi si w karcie gwarancyjnej WYMIANA BEZPIECZNIKA Przepalony bezpiecznik to najcz stsza przyczyna awarii kompresora Bezpiecznik przeznaczony do samo dzielnej wymiany jest zamontowany na spodzie...

Page 11: ...TEJ CZYNNO CI NALE Y W O Y NOWY BEZPIECZNIK DO UCHWYTU NALE Y ODKR CI RUBOKR TEM UCHWYT POD KT RYM ZNAJDUJE SI BEZPIECZNIK NAST PNIE NALE Y WYJ BEZPIECZNIK Z UCHWYTU NAST PNIE NALE Y W O Y UCHWYT Z NO...

Page 12: ...wy cznie produkty sprawdzone pod wzgl dem materia owym jako ciowym i funkcjonalnym Je eli maj Pa stwo pytania dotycz ce procedury serwisowej prosimy o kon takt 9 OZNACZENIA 10 POLECANE PRODUKTY W ofe...

Page 13: ...11 PL NOTATKI instrukcja_A5_TGR Y MB 001 1_pol ang indd 11 instrukcja_A5_TGR Y MB 001 1_pol ang indd 11 2016 09 05 18 24 39 2016 09 05 18 24 39...

Page 14: ...instrukcja_A5_TGR Y MB 001 1_pol ang indd 12 instrukcja_A5_TGR Y MB 001 1_pol ang indd 12 2016 09 05 18 24 39 2016 09 05 18 24 39...

Page 15: ...quality products We have many years of experience in this sector Tima go products reach a wide range of users in Poland and throughout Europe through our distributors medical retailers Timago s compa...

Page 16: ...ng pres sure pump Air cell mattress Repair kit patch glue Spare fuse Air hoses 3 INDICATIONS Anti decubitus bubble mattress with pump are aids for people at risk of bed sores They are used for people...

Page 17: ...ss should be connected with air hoses so that they are not kinked or trapped under the mattress Make sure that the hoses are properly fastened and do not come out from the ports STEP 4 Plug in the pum...

Page 18: ...E MATTRESS AGAIN THE STARTING PROCEDURE MUST BE PERFORMED SEE STEPS 6 AND 7 MATTRESS AIR PUMP MATTRESS DIMENSIONS 200 X 90 X 7 CM WEIGHT 2 KG 1 5 KG MAXIMUM WEIGHT CAPACITY DO 110 KG CYCLE DURATION 12...

Page 19: ...T DIAL AIR PUMP HOOK PUMP 220V 50HZ MOTOR SWITCH 2 SWITCH 1 DIAGRAM OF THE SOFT WIND III ELECTRICAL DIAGRAM instrukcja_A5_TGR Y MB 001 1_pol ang indd 17 instrukcja_A5_TGR Y MB 001 1_pol ang indd 17 20...

Page 20: ...AGAINST SHARP OBJECTS AND SHOULD NOT BE LAID DIRECTLY ON BED SPRINGS OR BED FRAMES WITH SHARP EDGES THE AIR PUMP SHOULD NOT BE USED IF THE POWER CORD OR PLUG IS DAMAGED OR IN CASE OF APPARENT PROD UC...

Page 21: ...R OWN WE ONLY RECOMMEND USING REPLACEMENT PARTS FROM THE MANUFACTURER PLEASE CONTACT YOUR RETAILER AS REQUIRED A WORN OUT OR DAMAGED AIR PUMP SHOULD BE TAKEN TO AN ELECTRICAL OR ELECTRONIC RECYCLING C...

Page 22: ...fuse A spare fuse is provided with the mattress CLEANING The mattress and the air pump should be cleaned with a damp cloth using mild cleaning products certified by the National Institute of Hygiene...

Page 23: ...ER WITH THE FUSE INSTALLED NEXT INSERT A NEW FUSE INTO THE HOLDER USING A SCREWDRIVER UNSCREW THE HOLDER WHICH COVERS THE FUSE THEN REMOVE THE FUSE FROM THE HOLDER THEN REPLACE THE HOLDER WITH THE NEW...

Page 24: ...red by Timago Interna tional Group include Orthotics and joint stabilizers Manual and special use wheel chairs Walkers and walking aids Crutches and canes Rehabilitation beds Adaptive and bathroom equ...

Page 25: ...23 EN NOTES instrukcja_A5_TGR Y MB 001 1_pol ang indd 23 instrukcja_A5_TGR Y MB 001 1_pol ang indd 23 2016 09 05 18 24 40 2016 09 05 18 24 40...

Page 26: ...instrukcja_A5_TGR Y MB 001 1_pol ang indd 24 instrukcja_A5_TGR Y MB 001 1_pol ang indd 24 2016 09 05 18 24 40 2016 09 05 18 24 40...

Page 27: ...instrukcja_A5_TGR Y MB 001 1_pol ang indd III instrukcja_A5_TGR Y MB 001 1_pol ang indd III 2016 09 05 18 24 40 2016 09 05 18 24 40...

Page 28: ...M Timago International Group Sp ka z o o i Sp ka Sp ka komandytowa ul Karpacka 24 12 43 316 Bielsko Bia a Polska T 48 33 499 50 00 F 48 33 499 50 11 E info timago com Wydanie II Data aktualizacji 15 0...

Reviews: