background image

Page

| 6

.

CONNECTION TO CHIMNEY

After getting familiar with your stove and its part and before you connect it to a chimney, check the quality of

the chimey. If the chimeny is not highest quality we recommend that stove pipe sections should be attached

to the cooker throught fume exit  on the top side . Attach the stove pipe to the stove's flue collar, with sheet

metal screws.

Exhaust pipes and connection to chimney must go up ways

Horizontal parts of fumepipes should not be longer than 0,5m  and they should always rise away

from stove  a minimum of 10  torward chimeny.

Fume pipes diameter should  not get  smaller.

All connections must be tight , pipes and chimney must be clean and without any kind of dirt.

Chimney must be protected  from cold (insulated) especially  in the case of metal chimney  and in

the case of exterior masonry chimney.

Non vertical  fume pipes which don’t have insulation should not be longer than 1,25m

Chimney  must fulfill  the following conditions:

Chimney  goes above roof minimum 0,5m.

Chimney should be higher than the firs house next to it, higher  than tree or any other obstacle.

Interior chimney is preferable and exterior chimney must be well insulated.

Chimney must be clean of any kind of dirt, bird nests or any kind of

Stovepipe must not be attached to deep in to chimney because it decrease fuming out .

All unnecessary holes or cleaning doors on the chimney must be closed.