26
on the generator and engine.
!
For long term storage, either drain fuel into suitable container or add a fuel
preservative/stabilizer (not included) to prevent fuel breakdown.
!
After each use, unplug all tools and equipment from the generator.
!
After the engine and generator have completely cooled, store the generator in a safe, clean and
dry location (if not permanently installed).
STORAGE
Before storing the unit for an extended period:
!
Be sure the storage area is free of excessive humidity and dust.
!
Service according to the table below:
STORAGE TIME
RECOMMENDED SERVICE PROCEDURE
Less than 1 month
No preparation required.
1 to 2 months
Fill with fresh gasoline and add gasoline conditioner.
2 months to 1 year
Fill with fresh gasoline and add gasoline conditioner. Drain the carburetor
float bowl. Drain the fuel sediment cup.
1 year or more
Fill with fresh gasoline and add gasoline conditioner. Drain the carburetor
float bowl. Drain the fuel sediment cup. Remove the spark plug and put a
tablespoon of engine oil into the cylinder head. Pull recoil starter slowly to
distribute the oil evenly in the cylinder. Reinstall the spark plug. Change
the engine oil. After removal from storage, drain the stored gasoline into a
suitable container and fill the generator tank with fresh gasoline before
starting.
INSTALLATION
Your generator may be installed as part of an Automatic Generator System (AGS) but should only
be done so by a certified electrician and licensed contractor. Note the following if you decide to
permanently install your generator:
Electrical and other permits may be required for the installation of
emergency power systems. Investigate your local building and electrical
codes before installing this unit. Installation must be completed by a
certified electrician and licensed contractor.
Prior to powering tools and equipment make sure the generator’s rated
voltage, wattage and amperage capacity is adequate to supply all electrical
loads that the unit will power. If powering exceeds the generator’s capacity,
it may be necessary to group one or more of the tools and/or equipment for
connection to a separate generator.
WARNING! THE GENERATOR WEIGHS APPROXIMATELY 110
POUNDS. USE CARE AND THE PROPER LIFTING OR HOISTING
EQUIPMENT WHEN MOVING IT TO THE INSTALLATION
LOCATION. ALWAYS CONNECT HOIST LINES TO THE FRAME
OF THE GENERATOR.