Tilia Termoventiler ThermOmatic ERA 10 Installation And User Instructions Manual Download Page 4

Termoventiler AB

4

The direction of movement of the mixing valve motor
is set using the dial for max setting as follows.

See 

1. Installation of bypass valve

 on previous page to

determine in which direction the mixing valve should
close.

If the power is connected when the max dial is at an
end point, the red+yellow light will blink for 5
seconds at the same time. The direction of movement
can be set during this time.

Alt 1: 

If the mixing valve closes clockwise (B, D);

set max limit dial at 20° (Pic 2).
Switch on power. To adjust clockwise closing, you
only need to turn the dial clockwise to 80° within 5
secs.

Alt 2: 

If the mixing valve closes the motor

anticlockwise (A, C);

 set max limit dial to 80° (Pic 3).

Switch on power. To adjust anticlockwise closing, you
only need to turn the dial clockwise to 20° within 5
secs

The direction of movement setting stays the same after
a power loss.

3. Mounting mixing valve motor on
mixing valve

Mount motor on bypass valve as follows:

a) Mount motor mounting on lower right mounting (2

on picture below).

b) Press spindle sleeve (1 in picture) on mixing valve

spindle so spindle reaches bottom of hole. Check that
the arrow points to 5 on bypass valve gauge.

c) Check that dial is in operating position. Dial has

two positions;
1. Manual position = Dial pushed out and can be
turned.
2 Operating postion = Dial is at furthest point
(locked towards motor) and cannot be turned.

d) Guide motor onto spindle sleeve and push it firmly

into position. Fix motor with screws (3 on picture)
in centre of dial.

a) Switch on power. NOTE The room sensor should

not be connected.

b) Check that motor goes to closed position and then

opens in 20 seconds.

c) If motor does not go to closed position –

disconnect power and follow instructions to
change direction of movement. Test again .

d) Mount the blue-red scale (4 on picture above)

such that the blue field points towards the red
arrow on motor. Push top firmly into position (5
on pic).

e) Disconnect power by removing network adapter.

Picture 2

Picture 3

4. Installation/checking of direction of movement

Summary of Contents for Termoventiler ThermOmatic ERA 10

Page 1: ... the yellow light comes on when the motor closes the valve If the max setting dial is turned to the end point at start up the red yellow light will blink for five seconds The direction of movement can be set during this time When the motor reaches an end point the red or yellow light will blink The red light blinks when there is no more heat in the boiler storage tank The yellow light blinks when ...

Page 2: ...g 12 Manual adjustment DClockwise closing CAnticlockwise closing BClockwise closing 1 Installation of bypass valve 3 Mounting of mixing valve motor to mixing valve 2 Connection of cables 4 Installation checking of direction of movement 5 Installation of flow sensor 6 Placement of room sensor Alternative order of installation e g if mixing valve is readily accessible 7 Mounting of room sensor 8 Com...

Page 3: ... sensor to plinth Connect cable to room sensor to plinth DO NOT connect the room sensor itself 2 Connection of cables NOTE This can be easier to do before mounting the ERA on mixing valve Cable ends 4 mm Picture 4 Picture 3 Push in firmly and hold cables firmly in cable outlet till cover catch secures them Picture 5 Unscrew screws Picture 1 Indicator arrow Picture 2 Plinth for connecting cables 24...

Page 4: ...alve Mount motor on bypass valve as follows a Mount motor mounting on lower right mounting 2 on picture below b Press spindle sleeve 1 in picture on mixing valve spindle so spindle reaches bottom of hole Check that the arrow points to 5 on bypass valve gauge c Check that dial is in operating position Dial has two positions 1 Manual position Dial pushed out and can be turned 2 Operating postion Dia...

Page 5: ...he network light will illuminate continuously ERA is now ready for use Set the room sensor to the desired tempera ture 9 Radiator thermostats The thermostat part should be removed from any thermostat valves in the same room as the indoor sensor In other rooms it is an advantage to have thermostat valves that can shut off the radiator if the room gets too hot due to supplementary heat 10 Adjusting ...

Page 6: ... or heating pump Balancing makes the return temperature as low as possible which increases the storage capacity of the tank and the effectiveness of the pump Fault tracing For ease of installation and fault tracing ERA immediately goes into start up mode for 30 minutes every time the power is connected If the max setting dial is at an end point at start up the red yellow light will blink for 5 sec...

Page 7: ...gh Thermomatic ERA is in fully closed position Motor closed position and mixing valve 0 position not synchronised Remove motor from mixing valve Set mixing valve to 0 Re attach motor fully closed Motor will only open or close Wrong direction of movement Change motor s direction of movement See page 4 for instructions Motor is not opening far enough even though house is not warm Max setting set too...

Page 8: ...Termoventiler AB 8 ...

Reviews: