The motor is midway between closed and open on
delivery (Picture 1).
a) Depress and turn dial approx. 1/8 turn towards stop.
The dial will then remain in depressed position when
cover is removed.
b) Remove cover by unscrewing screws with crosshead
screwdriver. DO NOT turn dial until cover is
screwed back into place (Picture 1)
c) Connect cables:
The ends of the cables should be stripped to max 4
mm (See sketch).
Connect power cable to plinth as shown in
picture 2.
Connect flow sensor to plinth.
Connect
cable
to room sensor to plinth. DO
NOT connect the room sensor itself.
2. Connection of cables.
NOTE This can be easier to do before mounting the ERA on mixing valve.
Cable ends
4 mm
Picture 4
Picture 3
Push in firmly
and hold cables
firmly in cable
outlet till cover
catch secures
them
Picture 5
Unscrew screws
Picture 1
Indicator arrow
Picture 2
Plinth for connecting cables
24V
Flow sensor
Room sensor
d) Press in carefully and hold cables in position in
cable outlet such that the locking catch on the
casing can secure them in position
(Pictures 3 and 4).
e) Mount casing onto motor. Tighten screws.
(Picture 5)
f ) Turn back dial so it pops out into operating posi-
tion.