TECHNISONIC INDUSTRIES LIMITED
RC-9100 Installation Instructions
TiL 14RE508 Rev. B Issue 1
10
CONDITIONS
SECTION
CATEGORY
COMMENTS
Decompression
4.6.2
50,000 feet
Overpressure
4.6.3
- 15,000 feet
Temperature Variation
5.0
B
+/- 5 degrees C per minute
Humidity
6.0
A
Standard Humidity Environment
Operational Shock and Crash Safety
7.0
B
Standard Operational Shocks
Vibration
8.0
S
Sinusoidal Vibration – curve M
S
Random Vibration – curve B
U
Sine-On-Random Vibration – curve G
Explosive Atmosphere
9.0
X
Not tested
Waterproofness
10.0
X
Not tested
Fluids Susceptibility
11.0
X
Not tested
Sand and Dust
12.0
X
Not tested
Fungus
13.0
X
Not tested
Salt Fog Test
14.0
X
Not tested
Magnetic Effect
15.0
Z
Distance result was 0.21 meters
Power Input
16.0
B
See NOTE-2
Voltage Spike
17.0
B
Audio Frequency Susceptibility
18.0
B
Induced Signal Susceptibility
19.0
AC
Radio Frequency Susceptibility
20.0
T
See NOTE-1
Radio Frequency Emission
21.0
M
See NOTE-1
Lightning Induced Transient Susceptibility
22.0
X
Not tested
Lightning Direct Effects
23.0
X
Not tested
Icing
24.0
X
Not tested
Electrostatic Discharge
25.0
A
10 discharge locations were used
Fire, Flammability
26.0
C
Flammability – See NOTE-3
Other Tests
Remarks:
All testing was performed at Technisonic Industries unless otherwise indicated.
NOTE-1
Indicated test was performed by ULTRATECH LABS.
NOTE-2
Testing included subparagraph 16.6.1.3b: Requirement for Equipment with Digital Circuits.
NOTE-3
Only applies to units with Mod 6 marked on the modifications label.