15
4 Second Calibration Delay
Sets a 4 second delay before TigerGauge will zero. This requires the user to hold the calibrate button
until the screen countdown is complete to be zeroed.
P
*
Press
to scroll through the options.
Options
ON -
TigerGauge zeros by holding
for 4 seconds.
OFF -
TigerGauge zeros immediately when you press
.
Reset Reference
Reset Reference will tell TigerGauge to use the calibrate button to reset the Reference setting, instead of
zeroing. When in this mode, TigerGauge cannot be zeroed.
P
*
Press
to scroll through the options.
Options
ON -
Resets the Reference setting when
is pressed.
Note: TigerGauge cannot be zeroed in this mode.
OFF -
TigerGauge will zero when you press
.
Incremental Measurement
Turns on TigerGauge’s incremental measurement mode. This allows the user to set a second zero point
while measuring to see how far one measurement is from another.
P
*
Press
to scroll through the options.
Options
ON -
Puts TigerGauge in incremental measurement mode.
OFF -
Turns off incremental measurement mode.
Using Incremental Measurement Mode
1. Measure a part normally.
2. Press
at the same time to toggle to incremental mode. TigerGauge will display 0.
Note: The screen will display
when in Incremental Measurement mode.
3. Make your second measurement and record the value.
4. Press
to return to your original calibration.