ESC Installation & User's Guide
12
Fig. 6
5. In the 1. Serial Settings (Fig. 12) parameters, change Baud Rate to 115,200 as shown in
the example, or to whatever baud rate is set in the controller.
6. In the 3. Passive Connection (Fig. 12) parameters, change Local Port to 14001, and click
OK.
The Local Port needs to be 11000 higher than the port setting in the Redirector. The other
Advanced settings should be left at their factory defaults.
If you will use two Local Ports, go back to step 2, Configure, and set up the second port the
same way. When you are back at step 6, change the Local Port to 14002.
The Configure Device screen (Fig. 7) reappears.
Fig. 7
7. Click
Apply
. The program should now update the settings and reboot the device.
When in use, both ports should have a baud rate matching the controller baud setting, 115200. (The factory
default is 9600.) Also be sure that Data bits = 8, Parity = None, Stop bits = 1, Flow control = none. (These should
be the factory default settings.)